Before any intervention requiring removal of the access panel or involving manipulation of the hydraulic con-
nections, the heat pump should be disconnected from its power source: during installation, carry out hydraulic
connections before wiring the machine in, disconnect the electricity before undoing the hydraulic connections.
Physico-chemical parameters of pool water :
Pool water treatment products currently available on the market are compatible with the materials used to make
the heat pumps, it being assumed that the pool water physico-chemical properties comply with the following
recommendations:
pH between 7 and 7.4
total hardness (TH) less than 200ppm
cyanuric acid content (stabiliser) less than 80 ppm
Concentration of free chlorine: 1.0 to 1.5 ppm
Concentration of free bromine: 1.0 to 1.5 ppm
These properties must be verified at the beginning of the season before allowing water to circulate through the heat
pump and regularly after this.
Caution:
Shock treatment of the pool water: should it be necessary to carry out a shock treatment of the pool water, first
isolate the hydraulic circuit (isolating valves) to which the heat pump is connected before beginning to increase
the concentration of disinfectant, and wait until the concentration of disinfectant returns to its normal value
before re-opening these valves.
Minimising heat loss:
During the initial heating phase at the beginning of the season, cover the pool with an isothermal cover to limit heat
loss through water evaporation and thermal transfer between the pool water and the overlying air.
To render this phase as short as possible, the heat pump (and hence the filtration system) should be left on 24 hours
a day. After the initial heating phase, the pool should be left covered with an isothermal cover when the pool is not in
use, especially when the ambient temperature is cool (night, etc.).
III. Siting and installation
HC-HH series CLIMEXEL heat pumps must be installed outside at a distance of at least 3.5m from the pool in
order to comply with the standard C 15-100.
We recommend that the heat pump be placed on a support on the ground next to the pool plant room. The following
recommendations should be respected :
- ensure easy accessibility around the machine to facilitate maintenance and cleaning;
- do not expose the heat pump directly to prevailing winds to limit splashing of the machine with water in the event of
precipitation; if necessary, install deflectors to protect the machine against this phenomenon taking care not to obstruct
the circulation of air into an out of the heat pump (minimum distances).
Vibration damping feet
Comes with 4 vibration damping feet to be screwed onto either end of the two profiles located under the machine. The
feet can be fixed to the support base to immobilise the machine (at least 2 screws per foot, screws are not provided).
2009/01 - Indice de révision : C - Code : 0033385