Model
Type
Splitting force
Log length
Log diameter
Stroke
Feed speed
Return speed
Hydraulic oil (max.)
Hydraulic pressure
Electric motor performance (power consumption)
Power supply
Dimensions
Weight
Problem
Logs are not being split properly
(insufficient splitting performance)
Splitting column moves unsteadily
or with strong vibrations
Splitting column does not move
Motor starts up but splitting
column does not move
Motor will not start
T
e
c
h
T
e
c
h
P
o
s
s
i
b
P
o
s
s
i
b
possible cause
⇒ The log is not positioned correctly
⇒ The log exceeds the maximum dimensions
or the wood is too hard for the
performance of the machine
⇒ Splitting blade does not split log
⇒ Hydraulic pressure too low
⇒ Release rods bent (hydraulic tappet not
quite pressed in)
⇒ Incorrect connecting lead (longer than 10
m or too small cable cross-section)
⇒ Air in the circuit
⇒ Splitting column not sufficiently lubricated
or oiled.
⇒ Hydraulic pump defective
⇒ Motor turns in wrong direction
⇒ No electrical power
⇒ 2-phase mode in threephase motor
⇒ Connection cable defective
⇒ Electric motor defective
n
i
c
a
l
d
a
t
a
n
i
c
a
l
d
a
t
a
l
e
p
r
o
b
l
e
m
s
l
e
p
r
o
b
l
e
m
s
remedy
⇒ Reposition the log correctly
⇒ Cut the log to the required dimensions
⇒ Sharpen splitting blade, check for burrs or
notches
⇒ Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ Arrange for manufacturer or authorised company
to adjust the rods
⇒ Use the correct connecting lead
⇒ Check the oil level and add more oil if necessary.
⇒ Lubricate
environmentally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
⇒ Check the motor direction
Threephase: adjust the motor direction (s. page
18)
AC: To correct the problem, refer to the manu-
facturer or other approved service centre.
⇒ Check the fuse.
⇒ Have fuse and lead checked by qualified
electrician.
⇒ Replace the connection cable or have it checked
by an electrician.
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
22
55 kN (5.5 t) ± 10 %
min. 100 – max. 300 mm
20 MPa (200 bar)
AC P
= 3500 W (S6-40%)
1
Threephase P
= 3000 W (S6-40%)
1
AC 230 V ~ 50 Hz, 16 A inert
Threephase 400 V 3~ 50 Hz, 16 A
Length 740 x Width 500 x Height 1520 mm
splitting
column
ASP 5,5
ASP 5,5
max. 1050 mm
≈ 500 mm
ca. 0,06 m/sec.
ca. 0,13 m/sec.
4,0 litres
ca. 96 kg
or
oil
with