6 Troubleshooting

SYMPTOMS
Display
switches on
when button
is pressed
Display OFF
Display still
off when
button is
pressed
System and data display 7
switched on in red
Data display
The unit
7 switched on
cannot be
in red
controlled
via DMX
Data display
(inactivated
7 switched on
wireless
in green
DMX)
When using several units,
dimming are not
synchronized
Light switches on when
powered on
Light switches on when
using the control board
Strobe function doesn't work
POSSIBLE REASONS
Display auto off mode
activated
No power
Problem with the DMX512
received signal and/or system
default – details available in
4/6 Fixture Tools menu
DMX protocol problem
Data cabling problem
DMX address
The strobe is active and the
channel value is void
Different Resolution
Different smoothing
Different Dimming curve
Manual value is operating
when DMX is not connected
Use of the Focus mode
Strobe function inactive
Strobe function active
EN -23-
SOLUTIONS
Fixture tools menu
Display mode (see
4.9.2)
Check :
power supply
thermal protection
the power supply connector must be
properly interlocked
Failure details are available in 4/6 Fixture
Tools menu
Check data signal
Check cabling and data
connectors
Check the DMX
address
The value must be 255 (100%) in order to
have the light intensity dimmed
All the units must have the same resolution
(See 4.9.2 Fixture param.
All the units must have the same smoothing
(See 4.9.2 Fixture param menu
Smoothing)
All the units must have the same dimming
curve (See 4.9.2 Fixture param menu
Light Curve)
Local values must be at zero
See 4.9.2
Strobe must be activated in Fixture param.
menu
Strobe Control
Control channel must be higher than 0
EN
The received data
protocol can be
checked in the
Fixture tools menu
Resolution)