Analysis; Led Reaction According To Led Temperature; Thermal Protection; Adjusting The Maximum Light Output Level - Robert Juliat 533 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.1.4
LED source
• Do not touch the surface of the LED source (no contact with your hands or any tools).
• Do not put compressed air directly on the source.
• Contact a certified RJ distributor in case of residuals or other objects located on the
surface of the LED source.
5.1.5
Optics
The cleaning of optical parts (lenses) shall be carried out with solutions containing alcohol.
5.2

Analysis

If there is still a problem after the troubleshooting procedures (see part 6.), contact RJ distributor with
the following information:
Model, version and serial number of the product.
Software version (available in menu 5/6 Fixture Info)
Description of the problem.
5.3

LED reaction according to LED temperature

LED temperature
5°C
60°C
60°C
70°C
70°C
90°C
5.4

Thermal protection

In case of thermal protection start 4:
Remove the LED compartment (See 5.1.4 Dismantling the LED compartment).
Control possible overheating indications.
Reassemble the LED compartment.
Reset the thermal protection by pressing the button.
5.5

Adjusting the maximum light output level

The maximum intensity level of the LED source can be adjusted in the 3/6 Fixture Param.
setting menu in order to have a consistent fixture fleet. The dimming level is then recalculated
depending on the limitation.
5.6

Exploded view / Spare parts list

Available on
www.robertjuliat.com
Lens tube access
Fan rotation at minimum level
Fan rotation increases progressively
Fan at maximum speed
LED intensity dims to zero output (overheating protection)
DMX and system LED feedback is red and temperature is available in
4/6 Fixture Tools menu
EN -22-
Fan
EN
Maximum

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

533c

Table des Matières