Troubleshooting; Possible Causes - Robert Juliat ALEDIN T 630SX-CW Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Robert Juliat | T630SX

6 Troubleshooting

SYMPTOMS
Display
switch on
when button
pressed
Display OFF
Display still
off when
button
pressed
"senerr"
"fanerr"
Error
message
displayed
"heat"
DMX
indicator on
Impossible
to command
DMX
by DMX
indicator off
When using several units,
dimming are not
synchronized
Light switch on when
powered on
Light switch off when DMX
not detected
Strobe function doesn't work

POSSIBLE CAUSES

Display auto off mode
activated
No power
Temperature sensor is either
not connected or not working.
Fan is not connected or not
working.
Ambient temperature has
reached point where fan
cannot cool LED sufficiently;
LED will therefore begin
dimming to protect LED from
overheating.
DMX address
DMX protocol problem
DMX data wiring
Different Resolution
Different Response
Different Dimming curve
Manual value is operating
when DMX is not connected
Manual or OFF mode are
active when DMX is not
connected
Strobe function inactive
Strobe function active
- 32 -
SOLUTIONS
Menu Pers à disp (see 4.4.2)
Check power supply
Check LED connector
Test the fan manually (Menu Tools
tstFan)
Set up fan speed limit to HIGH (Menu Pers
Fan)
See 3.1.2 operation conditions
Check DMX address
Check data signal
Check connectors and
data cable
All the units must have the same resolution
(See 4.4.2 Menu Mode à Resolution)
All the units must have the same response
(See 4.4.2 Menu Mode à Response)
All the units must have the same dimming
curve (See 4.4.2 Menu Mode à Curve)
Select OFF or HOLD mode in Menu Pers
noDMX,
Select HOLD mode in Menu Pers
Strobe must be activated in Menu Mode à
Strobe
Light intensity must be different from 0
DMX data
detected can be
check in Menu
Tools à DMXin
noDMX,

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Aledin t 630sx-ww

Table des Matières