Feedback Information; Service; Preventive Maintenance; General Cleaning - Robert Juliat 533 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.9.4
Reset
Reset to default settings:
Hard reset (parameters saved):
4.9.5

Feedback information

DMX and system LED feedback 7:
Green= DMX512 frame detected
Red = Problem on DMX512 frame and/or system default – details available in 4/6
Fixture Tools menu
If DMX512 data lost, the following message is displayed:
The last received DMX values are stored but it is possible to inactivate the current values by
pressing the Select key (as well as the Master function) in order to get a total control of the
fixture locally. When a DMX signal is detected, the DMX control is active again.
¥
signal indicates a wireless DMX:
Signal
Switched off – no symbol
Slow intermittent display
Continuous display
Rapid intermittent display

5 Service

5.1

Preventive maintenance

5.1.1
Frequency
General maintenance should be performed at least once a year or more frequently if the equipment is
operated in adverse conditions (smoke, heat, humidity, touring, etc.).
5.1.2

General cleaning

Remove dust from the unit (air vents, printed circuit boards, etc.).
During cleaning:
LED must be protected to avoid dust on it.
Fan blades must be locked.
5.1.3

General visual check

No trace of heat.
No loose contacts.
No missing parts.
Tighten mechanical assemblies (screws, bolts and nuts, ground connections, etc.).
Menu: 4/6 Fixture tools
Push Hard CPU reset button (6)
"Push select to reset DMX values"
The fixture is not paired with a transmitter
The fixture is paired with a transmitter but the DMX signal is not
detected
The fixture is paired with a transmitter and the DMX signal is
detected
Lost connection with the transmitter or in connection with the
transmitter
8/8 Reset fixture
select
Information
EN -21-
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

533c

Table des Matières