NOTE: Ensure the gas supply to the appliance is turned "ON".
During the initial ignition cycle, air must be purged from the
gas line and thus it may take one to two minutes for the pilot
burner to ignite.

M,MS Models

Pilot Lighting Instructions

1. The in-line service shut-off valve should be in the "ON"
position.
2. With a lighted taper light the pilots which are located at
the rear of the main burner.
3. The pilot fl ame should be approximately 7/8"
(22 mm) long for proper ignition of the burners. The
pilot adjustment valve is located by sliding the drip
tray forward. The adjustment valves are located on the
manifold pipe, which runs horizontally across the back of
the unit, behind the drip tray, one is at the left rear and
the other is at the right rear.
4. To adjust the pilot light, turn the brass screw counter-
clockwise to increase the pilot fl ame, and clockwise to
decrease the fl ame.
NOTE: No more than 7/8" (22 mm) pilot fl ame length should
be required. Too high a setting will cause the fl ame to lift off
or will create excessive carboning. Do not adjust the pilot
fl ame lower than 7/8" (22mm) long because this can cause
delayed ignition at the burner. The delayed ignition could
cause the burner tiles to crack, in that case the burner would
have to be replaced.

Main Burner Operation

1. Turn the main burner to the "MAX" position.
2. Immediately check ignition of the burner.
CAUTION: Should ignition fail after fi ve (5) seconds, turn the
valve off and wait fi ve (5) minutes before trying again. The
pilot gas is not interrupted automatically, it is the responsibility
of the operator to check the ignition of the burners
immediately after the burner valve has been turned on.

Shut Down

1. Turn all valves to the "OFF" position by rotating the knob
clockwise 1/4 turn.
2. If the unit is to be shut down for an extended period of
time close the inline gas valve.
Page 8

MST Models

Operating Controls

Lighting Instructions

1. Push in the tap and turn it counter-clockwise to the
Ignition Position " "
2. Holding the tap fully in, light the pilot with a match or
taper.
Part # 1382684 Rev. 02 (11 Feb 2014)
OFF
IGNITION
MAX
MIN

Publicité

Chapitres

Table des Matières
loading

Table des Matières