Technical Data
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire connection:
Wire fixing:
Fixing torque:
Mounting:
Weight:

Dimensions

Width x height x depth:
UL-Data
Nominal voltage U
:
N
Ambient temperature:
Switching capacity:
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo

Standard Type

BD 5987.02/001 DC 24 V
Article number:
• Output:
• Nominal voltage U
:
N
• Width:

Troubleshooting

Failure
LED "Power" does not light up
LED "K2" lights up,
but "K3" remains off
LED "K3" lights up,
but "K2" remains off
Device cannot be activated

Maintenance and repairs

- The device contains no parts that require maintenance.
- In case of failure, do not open the device but send it to manufacturer
for repair.
Thermoplastic with V0 behaviour
according to Ul subject 94
Amplitude 0,35 mm IEC/EN 60 068-2-6
frequency 10 ... 55 Hz
15 / 055 / 04
IEC/EN 60 068-1
EN 50 005
1 x 4 mm
2
solid or
1 x 2,5 mm
2
stranded ferruled (isolated)
or
2 x 1,5 mm
stranded ferruled (isolated)
2
DIN 46 228-1/-2/-3/-4 or
2 x 2,5 mm
stranded ferruled
2
DIN 46 228-1/-2/-3
Plus-minus terminal scews
M3.5 box terminal with wire protection
0.8 Nm
DIN rail
IEC/EN 60 715
450 g
45 x 74 x 121 mm
AC 24, 42, 48, 110, 127, 230, 240 V
DC 24 V
- 15 ... + 55 °C
6 A, 250 Vac G.P.
60°C / 75°C copper conductors only
AWG 18 - 16 Torque 7 lb in
0040954
2 NO contacts
DC 24 V
45 mm
Potential cause
Power supply not connected
- Safety relay K2 is welded
(replace device)
- A 1-channel switch-off occurred on
S22, T22 e.g. S23
(switch channel off on S12 e.g. T12)
- Safety relay K3 is welded
(replace device)
- A 1-channel switch-off occurred on
S12 e.g. T12
(switch channel off on S22, T22 e.g.
S23)
- Safety relay is welded
(replace device)
- Manual start mode:
Line fault on start-button (disconnect
power supply and remove fault)
- Automatic start mode:
X5 - X6 e.g. T33 - X6
are not bridged

Variants

BD 5987.02/61:
with UL approval (Canada/USA)
BD 5987.02/001:
Optionally cross fault monitoring on the
emergency stop loop (see application M6749)
Optionally automatic On function when operating voltage
is applied or after activation by the On pushbutton.
Jumper asignment for functions:
Activation via On pushbutton / or automatic On function:
On pushbutton
Jumper
S12-S34 or
X5 - X6
S33-S34
M8687
BD 5987.03/001:
with 2 NO contacts,
1 signalling contact AC/DC 0,1 ... 1 A / 10 ...120 V
BD 5987.03/201:
see BD 5987.03/001,
but with special terminal designation
Jumper asignment for functions:
Activation via On pushbutton / or automatic On function
On pushbutton
Jumper
T11-T34 or
T33 - X6
T12-T34
M8687
BD 5987.02/301:
Starting behaviour as with BD 5987.02/001,
shorter release time when opening the supply circuit,
Suitable also for elevators according to EN 81-20/-50,
Complies to the requirements of the directive
2014/33/EU for elevators.
Ordering example for variants
BD 5987 .02
/_ _ _ AC 230 V
17
Function
The output contacts are switched only
after operation of the On pushbutton.
Line fault monitoring at the On push-
button.
Automatic On function for operating
voltage Off/On or after emergency-
stop release
Function
The output contacts are switched only
after operation of the On pushbutton.
Line fault monitoring at the On push-
button.
Automatic On function for operating
voltage Off/On or after emergency-
stop release
50/60 Hz
Nominal frequency
Nominal voltage
Variant, if required
Contacts
Type