Circuit Diagrams; Connection Terminals; Notes; Signal Description - DOLD SAFEMASTER BD 5987 Manuel D'utilisation

Module d'arrêt d'urgence
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Circuit Diagrams

A1
PE
13 23
S22
S33
Y1
Y2
(+)
(-)
A1 Y1
13
23
S12
S22
K2
S33
S34
K3
A2
Y2 PE
14
24
A2
14 24
S12 S12
S33 S33
S34
(-)
M7375_b
BD 5987.02
A1
S21
13 23
S12
S22
S23
S33
(+)
/PE
A1 X5
13
23
S12
S22
K2
S33
S34
K3
A2
X6 PE
14
24
A2
14 24
S12
S33
X5
X6
S34
(-)
M7376_b
BD 5987.02/001 + /301

Connection Terminals

Terminal designation
A1 (+)
A2 (-)
S12, S22, S23, S34, X6, Y2
T12, T22, T34
PE (-), S21/PE, S33, X5, Y1
T11, T12, T33
13, 14, 23, 24
33, 34

Notes

Line fault detection at the On pushbutton:
The output contacts cannot be closed if the On pushbutton is already
closed before the voltage is applied to S12, S22 (also in the event of a line
fault at the On pushbutton).
A line fault at the On pushbutton which occurs after activation of the de-
vice is recognized when switching- on takes place again and closing of the
output contacts is then prevented.
If a line fault occurs at the On pushbutton after the voltage is already
present at S12, S22 undesired activation will take place, because this line
fault does not differ from the normal closing function.
The gold-plated contacts of the BD 5987 mean that this module is also
suitable for switching small loads of 1 mVA ... 7 VA, 1 mW ... 7 W in the
range 0.1 ... 60 V, 1 ... 300 mA. The contacts also permit the maximum
switching current. However, since the gold plating will be burnt off at this
current level, the device is no longer suitable for switching small loads
after this.
The PE terminal permits operation of the device in IT systems with insula-
tion monitoring and also serves as a reference point for testing the control
voltage. The internal short-circuit protection will be bridged on DC devices,
if the protective ground is connected to terminal PE.
One or more extension modules BN 5989 or external contactors with for-
cibly guided contacts may be used to multiply the number of contacts of
the emergency stop module BD 5987.
For automatic restart:
S22 must be connected before S12. S12 initiates the automatic restart.
With manual restart it is not necessary to follow this order.
A1
S21
13 23
S12
S22
S23
S33
(+)
/PE
A1 X5
13
23
33
S12
S22
K2
S33
K1
S34
K3
A2
X6 PE
14
24
34
A2
14 24
33
34
X5
X6
S34
(-)
M7378_b
BD 5987.03/001
A1
13 23
T12
PE
T22
S23
T11
(+)
A1 T11
13
23
33
T12
T22
K2
T33
K1
T34
K3
A2
X6 PE
14
24
34
A2
14 24
33
34
T33
X6
T34
(-)
M7379_c
BD 5987.03/201

Signal description

+ / L
- / N
Inputs
Outputs
Forcibly guided NO contacts for
release circuit
Indicator output

Technical Data

Input
Nominal voltage U
:
N
Voltage range:
at 10% residual ripple:
at 48% residual ripple:
Nominal consumption:
Nominal frequency:
Control voltage at S33:
Control current
BD 5987.02:
BD 5987.02/001 + /301:
Minimum voltage at
terminals S12, S22:
Recovery time:
Output
Contacts
BD 5987.02:
BD 5987.03:
The NO contact 33-34 can only be used for monitoring.
Operate time:
BD 5987.02/001 + /301:
Release time
2-channel disconnecting in
secondary circuit
(S12, S22 and S23):
Opening in supply circuit
BD 5987.02:
BD 5987.02/001:
BD 5987.02/301:
Fault detection time at U
:
N
at 1-channel interruption
at S12:
BD 5987:
BD 5987/001+/201:
at S22 and S23:
Contact type:
Nominal output voltage:
Thermal current I
:
th
Switching capacity
contacts 13/14, 23/24:
to AC 15:
to AC 15:
to DC 13:
to DC 13:
contacts 33/34:
to AC 15:
to DC 13:
Electrical life
contacts 13/14, 23/24
at AC 230 V, 6 A, cos ϕ = 1:
contacts 33/34
at AC 230 V, 1 A, cos ϕ = 1:
Permissible operating
frequency:
max. AC 160 V or DC 160V for the variant BD 5987.02/301 when used
1)
in an elevator control acc. to elevator directive 2014/33/EU, if the
BD 5987.02/301 is not installed in a cabinet with prot. degree IP 54 or better.
Short circuit strength
max. fuse rating:
Mechanical life:
General Data
Operating mode:
Temperature range
operation:
storage :
altitude:
Clearance and creepage
distances
rated impuls voltage /
pollution degree:
EMC:
Interference suppression:
Degree of protection
Housing:
Terminals:
16
AC 24, 42, 48, 110, 127, 230, 240 V
DC 24 V
AC 0.8 ... 1.1 U
N
DC 0.9 ... 1.2 U
N
DC 0.8 ... 1.1 U
N
approx. 5.5 VA
50 / 60 Hz
DC 24 V
typ. DC 55 mA
typ. DC 45 mA
DC 21 V with activated device
0.5 s after release of the e-stop pushbutton
2 NO contacts
2 NO contacts, 1 NO contact used for
monitoring
max. 100 ms
with automatic restart approx. 1 s
50 ms ± 25 %
350 ms ± 50 %
120 ms ± 50 %
40 ms ± 50 %
typ. 430 ms
typ. 85 ms
50 ms ± 25 %
relay, forcibly guided
AC 250 V
1)
DC: see arc limit curve
see continuous current limit curve
(max. 10 A in one contact path)
3 A / AC 230V
IEC/EN 60 947-5-1
1)
6 A / AC 230V
at 0.25 Hz
1)
2 A / DC 24 V
IEC/EN 60 947-5-1
6 A / DC 24 V at 0.1 Hz
3 A / AC 230V
IEC/EN 60 947-5-1
2 A / DC 24 V
IEC/EN 60 947-5-1
> 5 x 10
switching cycles
5
> 5 x 10
switching cycles
5
600 switching cycles / h
6 A gG / gL
IEC/EN 60 947-5-1
10 x 10
switching cycles
6
Continuous operation
- 15 ... + 55°C
at max. 90 % humidity
- 25 ... + 85 °C
< 2.000 m
4 kV / 2 (basis insulation) IEC 60 664-1
IEC/EN 62 061
Limit value class B
EN 55 011
IP 40
IEC/EN 60 529
IP 20
IEC/EN 60 529
BD 5987 / 22.01.19 en / 088A