Cabinet Inclination And Inclined Multiplexing (Rif. 23) - Arneg Sendai Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

16 Hook the connection tray (S) to
the fan holder sheet using the
rectangular openings.
Remount the trays.
17 Connect the two control panels with the synchronisation cable for defrost (3).
(1) - Front cabinet (slave) controlled by the rear cabinet.
(2) - Rear cabinet (master)
(3) - Synchronisation cable
18 Connection:
1 - in the rear cabinet remove the front casing
2 - find the digital output "dig out" and connect the cable
3 - in the front cabinet remove the front casing
4 - in this case, the cable connected to the digital output "dig out" should be left
wound up and not connected.
5 - connect the cable on the rear cabinet to the digital input "dig in" on the front
cabinet.
6 - close the casings passing the cable over them.
19 Program the rear cabinet (2) using MASTER mode
Program the front cabinet (1) in SLAVE mode
20 Check that defrost occurs in both cabinets
N.B.The synchronisation cable (3) should not have any contact with moving parts
of the cabinet and should not be cut or damaged.

13.Cabinet inclination and inclined multiplexing (Rif. 23)

The Sendai cabinet has 3 possible inclinations, by adjusting the openings of the
removable supports (Part A):
horizontal: (opening the rear supports in line with the opening of the front supports)
4.5°: rear supports one opening higher than those of the front supports
9°: rear supports two openings higher than those of the front supports
05060048 01 13/06/2012
1
dig in
Sendai-SendaiR290
S
2
dig out
3
English
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sendair290

Table des Matières