Operating the Fire
WARNING: FAILURE TO FOLLOW THESE OPERATING INSTRUCTIONS MAY RESULT IN INJURY AND/OR
DAMAGE.
Manual Controls
The Opti-myst Manual controls are located on the base of the appliance.
(See Fig.2 for Manual Control lay out)
Switch 'A':- Controls the electricity supply to the Fire.
Note: This switch must be in the 'ON' ( I ) position for the Fire to operate with or without heat when activated.
Switch 'B':- Press
once to turn on the flame effect. This will be indicated by an audible "beep". Although the main
lights operate immediately it will take a further 45 seconds before the flame effect starts.
Press
to put fire into standby mode. This will be indicated by one "beep".
Remote Control
The remote control is packed with 2 AA batteries in a bag. Lift off the battery cover on the back of the remote control and
insert the batteries taking note of the polarity.
Switching on the appliance
Press and hold the ENTER button for 3 seconds to activate the remote control. FIRE will be displayed and ON will be
blinking. Press ENTER to swtich on the appliance. To turn off the appliance press MENU so that FIRE is blinking, press
ENTER twice.
Adjust the Flame Setting
With the remote control activated press once. FIRE will be blinking on the display. Press ENTER. The current flame
setting will be displayed F1-F6. Press the UP and DOWN buttons to adjust the setting. After you have selected your
flame setting press BACK twice to exit the menu and return to the home screen.
Switching on the Heat
With the remote control activated press MENU once. FIRE will be blinking on the display. Press ADV once, HEAT will
be blinking. Press ENTER. The current heat setting will be displayed OFF LO HI. Press the UP and DOWN buttons to
adjust the setting. After you have selected your flame setting press ENTER
Setting the Thermostat
The temperature shown on the display is the room temperature set point. This is the temperature that the heater will
maintain during the heating periods. If the room temperature is above this temperature then the heater will not operate.
The heater leaves the factory with this temperature set at 15ºC which represents a typical comfortable room temperature.
If you require a different room temperature then press either up or down on the home screen until the display shows the
temperature you require.
Thermal Safety Cut-out
A thermal safety cut-out is incorporated in the fan heater to prevent damage due to overheating. This can happen if
the heat outlet was restricted in any way. If the cut-out operates, unplug the heater from the socket outlet and allow
approximately 10 minutes before reconnecting. Before switching the heater back on remove any obstruction that may
be restricting the heat outlet, then continue normal operation.
CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be
supplied through an external switching device, such as a timer, or connected to a switch that is regularly switched on
and off by the utility.
Setting the Date and Time
To set the date and time on the heater;
1. Press the Menu button
2. Press ^ button 4 times
3. Press Enter when the Date & Time icon is blinking
4. Press Enter to set Time
5. Press v and ^ to set the Hour, press Enter
6. Press v and ^ to set the Minutes, press Enter to confirm the time
7. Press v and ^ to set the Day, press Enter
8. Press v and ^ to set the Month, press Enter
9. Press v and ^ to set the Year, press Enter to confirm the date