Venting Systems
A. Vertical - Interior - Typical Installation
PREFERRED METHOD #1
Flashing
Firestop
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
C. Vertical into Existing Class A Chimney
Flashing
Firestop
Ceiling Support
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
customerservice@ghpgroupinc.com
Rain Cap
12 in.
(305mm)
Minimum
10 in. (254mm) Min.
Clean-out T
Rain Cap
12 in. (305mm) Minimum
6 in. (152mm) Class A
Chimney Connector
Adapter
Follow vent manufacturer's
clearances for reduced clearances
6 in. (152mm) Flue
Connector
10 in. (254mm) Min.
Clean-out T
7077-171I • December 08, 2016
B. Through The Wall & Vertical - External -
Horizontal
PREFERRED METHOD #2
2 in. (5.08 mm) Minimum
6 in. (152 mm)
Minimum
Non-combustible Hearth Pad
We strongly recommend a minimum of 60
inches (1.5m) vertical, however above the
eave is preferred.
Both installations are approved for mobile home
installations. Must use 3 or 4 inch (76 to 102mm)
"L" or "PL" Listed pellet venting or Listed double
wall pipe and authorized Outside Air Kit in mobile
homes. Single wall pipe is approved for residential
installations only.
Air Clearance to Pipe
This appliance was tested with standard 3 inch
(76mm) Listed pellet vent.
Pellet pipe manufacturers Listed reduced clear-
ance pipe may be use for reduce clearance from
3 inch (76mm) air clearance to no less than 1 inch
(25mm) air clearance to combustibles for approved
Listed pellet pipe.
Follow pipe manufactures listed air clearances
to combustibles and installation instructions
for all reduced air clearances installations.
Rain Cap
12 in.
Flashing
(305mm)
Minimum
Support
Bracket
Every 60 in.
(1.5 m)
Wall Thimble
Tee
Clean-out Cover
: