Hearth Pad Requirements (Ul & Ulc) - Pleasant Hearth PH35PS Serie Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7
Dimensions and Clearances
E. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance "M" from the surface of the glass
door.
K
USA Hearth Pad Requirements
Hearth Pad Requirements
K
Sides
L*
Back
M
Front
Canada Hearth Pad Requirements
Hearth Pad Requirements
K
Sides
L*
Back
M
Front
26
L*
K
M
Inches
2
2
6
Millimeters
203
51
152
7077-171I • December 08, 2016
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
*E: Exception for Horizontal Installations:
CANADA INSTALLATIONS: A non combustible floor pro-
tections extending beneath the flue pipe is required with
horizontal venting or under the top vent adapter with verti-
cal installation.
USA INSTALLATIONS: A non-combustible floor protection
extending beneath the flue pipe is recommended with hori-
zontal venting or under the top vent adapter with vertical
installation.
A non combustible floor protector is required.
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over fire - If heater or chimney
connector glows, you are over firing. Over
firing will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to
comply may cause house fire.
WARNING
(877) 447- 4768

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ph50ps sériePh50cabps sériePh50ps seriePh50cabps serie

Table des Matières