"E‐1" Code On Control Board 1. Vacuum bypass chip missing.
Unit Shuts Down in 15‐20
minutes with an "E‐2" code
on control board.
"E‐3" Code on Control Board
(Overfire)
"E‐4" Code on Control Board
(Proof of flame lost)
Notes:
1. Whenever instructed to check/replace the vacuum sensor, also check for loose or cracked vacuum
hose. Also, be certain the vacuum measurement port in the firebox is kept clean (clean with a pipe
cleaner or brush, do not use a vacuum to clean).
2. To restart and clear an error code displayed on the control board, push the "ON" button and the
unit should reset the error and restart.
3. If you are uncertain about the meaning of an error code or have any questions at all, PLEASE
contact Technical Support at (800)245‐6489.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
2. Loose exhaust fan set screw.
1. Loose thermal sensor.
2. Control board settings.
3. Failure to light pellets.
1. Convection (Room Air) blower
failure.
2. Partially blocked flue.
3. Using fuel other than premium
wood pellets.
1. The hopper is empty.
2. The hopper lid was left open
too long during refueling.
3. Component failure.
4. Blower speed is set too high,
cooling firebox too rapidly.
47
2. Check set screw for tightness.
1. Contact Technical Support.
1. Check both sides of thermal
sensor connection (at exhaust
blower and at control board).
2. Start stove on minimum Heat
Range 5 to ensure a good fire is
started.
3. Check igniter for buildup or
failure.
1. Check convection blower for
proper function, replace if
necessary.
2. Check flue for obstructions.
3. Use ONLY premium wood
pellets in this stove.
1. Refill the hopper with pellets
and restart the stove.
2. Keep the hopper lid open for
the shortest interval possible
when refueling. The safety switch
stops the auger when the hopper
lid is open.
3. An auger motor failure or
combustion motor failure can
sometimes result in an "E‐4" code.
4. Operate the stove with the
blower speed and heat range at
the same value.