3. Accessories
Saw blades
en
4. Technical data
Right of technical changes reserved.
Power tool
Rated voltage
Rated current input
Mains frequency
Weight of power tool
Dimensions (L x W x H)
Stroke rate
Stroke
Blade holder
Protection class
5. Safety instructions
5.1 General Power Tool Safety Warnings
a)
WARNING
Read all safety warnings and instructions. Fail-
ure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference. The term "power tool" in the warnings
refers to your mains-operated (corded) power
tool or battery-operated (cordless) power tool.
5.1.1 Work area safety
a) Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
b) Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
c) Keep children and bystanders away while oper-
ating a power tool. Distractions can cause you to
lose control.
5.1.2 Electrical safety
a) Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
4
Printed: 07.07.2013 | Doc-Nr: PUB / 5071339 / 000 / 00
with ½" connection end
WSR 1000
120 V
9 A
60 Hz
3.3 kg (7.28 lb)
452 mm (17.8") x 97 mm (3.82") x 170 mm (6.69")
0...2,800/min
28 mm (1 ")
Keyless, for ½" standard blades
Electrical protection class II (double insulated)
tools. Unmodified plugs and matching outlets
will reduce risk of electric shock.
b) Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet con-
ditions. Water entering a power tool will increase
the risk of electric shock.
d) Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled cords
increase the risk of electric shock.
e) When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk
of electric shock.
f) If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces
the risk of electric shock.