Preparing for treatment
• Arrange yourself in front of the unit so you can relax
and enjoy the treatment of the part of the body con-
cerned.
• Tilt the lamp so the unit is angled directly at the part
of the body being treated.
• The distance to the infrared radiant heater depends
largely on personal heat sensitivity and the treatment
concerned.
• Make sure the distance between the infrared radi-
ant heater and the part of the body being treated
is not less than 30 cm!
• Protective eyewear which corresponds to the re-
quirements of DIN EN 171 2002 must be worn for
treatment distances under 30 cm. For treatment dis-
tances above 30 cm, closing your eyes is sufficient.
CAUTION
Never look directly into the infrared light without pro-
tective eyewear.
Do not use the unit for more than 15 minutes at a time
(risk of overheating). Allow the unit to cool down before
you use it again.
Treatment duration

Important

• Risk of burns: Remove any metal items, e.g. belt
buckles, necklaces, bras, jewellery or piercings, from
the treatment area before switching on the device as
they can become very hot.
We recommend short treatment times at the beginning.
However, even when the unit is used correctly, the skin
of some people can have an oversensitive or allergic
reaction to the heat treatment (e.g. intense redness,
blisters, itching, heavy sweating).
Starting the unit
Important
• Always close or cover your eyes when radiating the
face.
• Press the On/Off switch (3)
• The unit will turn on automatically after a short time.
• Set the time selector (5) to the desired duration (1 to
15 minutes).
• You can press the time selector (5) during operation
to reset the treatment duration.
• The infrared radiant heater switches off automatically
after the set time.
• For an additional treatment, you only need to press the
time selector (5) to reset your individual treatment time.
Important
• Do not touch the hot glass.
• To end treatment, use the On/Off switch (3) and dis-
connect the power plug.
During treatment
• Examine the part of the body treated frequently and
check for skin reactions. Cease exposure immediately
if there are any signs of oversensitivity or an allergic
reaction, and consult a doctor.
• The unit can be switched off at any time using the On/
Off switch (3).
• Do not cover up or pack the unit away while it is warm.
After treatment
• Switch off the unit at the On/Off switch (3).
• Pull the mains plug out of the socket.
6. Cleaning, changing the infrared
lamp, fuse and storage
Cleaning
Important
Before cleaning the unit, switch it off, unplug it and
allow it to cool down completely.
Important
• Ensure that no water enters the unit!
• Do not wash the unit in a dishwasher!
The unit can be cleaned with a damp cloth. Do not use
cleaning agents.
Replacing the fuse (UK plug only)
If the fuse needs replacing, please observe the
following:
• Remove the mains plug
• Lift out the fuse holder from the inside of the mains
plug using a flat screwdriver
• Pull out the fuse from the fuse holder and replace it
with a new fuse type: 3A (breaking capacity 6 kA at
240 V) in accordance with BS-1362 / SS167.
• Press the fuse holder containing the new fuse into
the plug slot
• Plug the mains plug into the socket,press ON/OFF
switch (3) and test to see if it works.
Changing the infrared lamp
Remember that a faulty lamp should only be replaced
with a lamp of the same type.
Warning
Danger of an electric shock!
• Before changing the lamp, make sure the power ca-
ble is unplugged from the socket.
• Risk of burning on hot surfaces!
• Allow the unit to cool completely before any repairs.
• Lamps are not covered by the guarantee.