Drainage
hole (on site)
Align the trough and screw it onto the wall (for ground mounting: align the legs and fix them with bolts to
the ground)
Install the drainage plug and tighten it well for more tension
Fix the drainage tube (tube DN 125)
Connect the valve body, the lever and the angle bracket > valve can be installed alternatively from the
right or the left side of the trough
Connect the water supply line ¾" > water connection can be done alternatively from beneath or from the
side (consider DIN 1988) > Water pressure max. 5 bar (73 psi).
connect the trough! If dirty water (sand, suspended matters) is given,
. Fix the frost protection guard (see mounting instructions of
Fix the heating element. Connect it to the electricity means of a transformer (see an additional mounting
instructions)
Install the bite protection plate to protect the connections
Fix the circuit pipe for the connection to the water circuit
(see the mounting instructions of the heating unit)
To ensure a frost-free feed pipe, wrap a frost protection heating cable around the pipe. Connect it to the
electricity means of a transformer.
The power supply cable, the heating cable and the insulation have to be protected against bites of
animals or damages > fix the biting protection shield
Heating spiral must
be connected to the
transformer.