How to use it:
• Place the appliance in the room half an hour before turning it on so that it becomes adjusted to the room temperature.
• Remove the appliance's water tank and unscrew the plug by turning it in an anti-clockwise direction.
• Fill the tank with distilled or demineralised water at a maximum temperature of 40°C. Check that the silicon washer is
correctly positioned, then close the cover by turning the latter in a clockwise direction.
• Make sure that the water tank is clean and watertight then carefully position it in the base unit.
• With dry hands, plug in and switch on the appliance. The indicator light comes on. The appliance begins to operate.
Adjust the intensity of the vapour as desired by turning the vapour intensity control button.
• Once the tank is empty, the safety mechanism inside the appliance will automatically stop the electricity supply if the
circuit is overheating. The indicator light turns red.
• Strict monitoring is required at all times to prevent any risk.
WARNING:
DESPITE THE SAFETY MECHANISM WHICH STOPS THE TRANSDUCER WORKING, AVOID AS MUCH AS POSSIBLE
LEAVING THE DEVICE PLUGGED IN WHEN NOT IN USE.
DO NOT CONNECT OR DISCONNECT THE ELECTRIC PLUG WITH WET HANDS.
MAINTENANCE AND STORAGE:
If the water is hard - in other words, if it contains too much calcium and magnesium - it can leave a «white powder» in
the appliance and cause heavy scaling on the surface of the tank, on the transducer (ceramic tablet which generates
ultrasounds) and on the internal walls of the water tank. Build-up on the surface of the transducer prevents the appliance
from working correctly.
We recommend:
1) Using boiled water which has been allowed to cool or distilled water each time,
2) cleaning the tank every 3 days and the transducer every week,
3) changing the water in the tank more often so that it is fresh, not leaving it in the appliance for more than 2 days,
4) Cleaning the appliance and making sure that all its components are completely dry when not in use.
To clean the transducer:
1) Pour 2 to 5 drops of vinegar on its surface and leave for a few minutes.
2) Brush the scale off the surface with a soft brush. Do not use a hard tool to scratch at the surface.
3) Rinse the transducer with clear water.
4) Do not use soap or other alkaline substances to clean the transducer.
To clean the tank unit:
1) Clean the water tank with a soft cloth and use vinegar if there is scale OR chalky deposits on its interior.
2) If there is scale covering the cut-out switch, pour a few drops of vinegar on it and clean with a brush.
3) Rinse the tank with clear water.
Storage:
1) Carefully clean and dry the ultrasound humidifier, following the maintenance instructions.
2) Let it dry completely before placing in storage. Do not store it with water remaining in the base.
3) Store the appliance in a cool and dry place away from children.