INSTRUCTIONS FOR USE
EN
Features:
• 1.8l capacity
• Continuous operation for more than 8 hours
• Easy-fill water tank
• Integrated safety mechanism which automatically stops the diffuser from working when the water tank is empty or
depending on the chosen diffusion period
• High-quality transducer guarantees correct and long-lasting operation
Functions:
• Increases and regulates the relative humidity of the room
• Eliminates electrostatic charges
• Improves air quality
Directions for use:
• Position the appliance in the room half an hour prior to switching it on so that it is the same temperature as the room.
• Remove the water tank from the appliance
• Fill the tank with distilled or demineralised water at a maximum temperature of 40°C
• The humidifier is equipped with a water filter. This especially helps deal with the calcium content of the water. To attach
this, attach the water filter to the inside of the tank cap.
• Check that the silicone washer is correctly in place and then close the cover by turning it clockwise.
• Make sure that it is clean and watertight then carefully position the tank in the base unit
• With dry hands, plug in and switch on the appliance. The yellow warning light which indicates that water is present
lights up. The appliance starts working on the low vapour intensity (warning light on)
• You can then adjust to the desired vapour intensity by turning the vapour output adjustment button
• You can also select the diffusion period (2 hours, 4 hours, 6 hours or 8 hours). To do this, press the diffusion period
adjustment button
• Once the tank is empty or the diffusion time has come to an end, the safety mechanism located inside the appliance will
automatically stop the electricity supply if the circuit is overheating The "water presence" warning light turns red
• Strict monitoring is required at all times to prevent any risk.
CAUTION: DESPITE THE SAFETY MACHANISM WHICH STOPS THE TRANSDUCER FROM WORKING,
WHENEVER POSSIBLE SWITCH OFF THE APPLIANCE WHEN NOT IN USE.
MAINTENANCE AND STORAGE:
If the water is hard, i.e. it contains a lot of calcium and magnesium, this can deposit a "white powder" inside the
appliance and cause a thick build-up on the surface of the basin, transducer (ceramic disc which produces the
ultrasounds) and interior walls of the water tank. Build-up on the surface of the transducer prevents the appliance from
working correctly.
We recommend:
1) always using water which has been boiled and then cooled or distilled water,
2) cleaning the tank every 3 days, cleaning the transducer every week,
3) changing the water in the tank regularly so that it is fresh, not leaving it in the appliance for more than 2 days,
4) cleaning the whole appliance and making sure that all its components are completely dry when not in use.
6
(Fig.
(Fig.
8).
2) and unscrew the cap by turning it anticlockwise
(Fig.
3).
(Fig.
4).
5).
(Fig.
(Fig.
6).
(Fig.
7).
(Fig.
9).