Installation
Connecting the luminaire without sen-
sors for operation with TouchDIM
This chapter applies only to luminaires with
the model number DPP xxx/D. The model
number can be found on the cover at the
luminaire head.
NOTE: Do not use a phase-cut dimmer. The
luminaire can be dimmed via TouchDIM.
N/DALI (black)
direct light
indirect light
Fig. 5: Connecting the luminaire without
sensors for operation with TouchDIM.
X Connect the wire rope at the connection
side of the luminaire to the protective
earth conductor terminal, see Fig. 5.
NOTE: TouchDIM and two switches
allow you to switch and dim the indi-
rect light and direct light of the luminaire
separately from each other.
X Connect the terminal to the mains and
the cables for the switch. For this pur-
pose, observe the circuit diagrams,
see chapter 12 "Circuit diagrams" , page
46.
X Clamp the connecting cable in the strain
relief A, see Fig. 3.
TouchDIM
Connecting the luminaire without sen-
sors for operation with DALI
This chapter applies only to luminaires with
the model number DPP xxx/D. The model
number can be found on the cover at the
luminaire head.
NOTE: Do not use a phase-cut dimmer. The
luminaire can be dimmed via DALI.
N/DALI (black)
direct light
indirect light
Fig. 6: Connecting the luminaire without
sensors for operation with DALI.
X Connect the wire rope at the connection
side of the luminaire to the protective
earth conductor terminal, see Fig. 6.
X Connect the terminal to the mains and
the cables for the DALI-bus. For this
purpose, observe the circuit diagrams,
see chapter 12 "Circuit diagrams" , page
46.
X Clamp the connecting cable in the strain
relief A, see Fig. 3.
ENG
DALI
DALI
35