INSTALLATION Continued
Further, if the unit is to be installed on a non-combustible
surface that is equipped with casters, means must be
provided to limit the movement of the unit with casters.
Final Gas Connection Review
Check all gas connections for leaks using a soapy solution
before lighting any pilots! DO NOT USE AN OPEN FLAME
TO CHECK FOR LEAKS! Putting an open flame beside a new
connection is not only dangerous, but will often miss small
leaks that a soapy solution would find.
All Garland appliances are adjusted and tested before
leaving the factory, effectively matching them to sea
level conditions. Adjustments and calibrations to assure
proper operation may be necessary on installation to meet
local conditions, low gas pressure, differences in altitude,
variations in gas characteristics, to correct possible problems
caused by rough handling or vibration during shipment, and
are to be performed only by qualified service personnel.
These adjustments are the responsibility of the customer,
installer and/or dealer and are not covered by the Garland
warranty.
All burners are equipped with continuous electronic spark
electrodes to insure flame is on at all times during operation.
Continuous sparking is intended to remain energized until
power is manually switched off.
WARNING: All connections must be sealed with a joint
compound suitable for LP gas, and all connections must be
tested with a soapy solution before lighting any pilots!
Start Up
Before initial lighting or if unit does not operate at all check
to see if:
1. Main gas supply shut off to appliance is open.
2. Electric power supply power and cord Nema 5-15P has
been plug into an appropriate 120V 15Amp 60Hz outlet.
Page 8
For daily start up:
1. Models HEEG-24CL and HEEG-36CL have one power
switch. Once pushed to the "ON" position an igniter
supplies a continuous spark to the burners igniting the
gas to all burners simultaneously. At the same time the
power switch opens up the gas flow to burners.
2. Models HEEG-48CL and HEEG-60CL have two power
switches which operate in the same manner as the
single switch above. Each switch operates separately
allowing the operator to run two sections of the broiler
independently. On the HEEG-48CL the switch on the far
left operates burners 1 to 4. The power switch on the
right will operate burners 5 to 9. On the HEEG-60CL the
left switch controls burners 1 to 6 and the right switch
controls burners 7 to 11.
3. If burners do not ignite, shutdown power to the unit,
and wait 5 minutes before repeating ignition. If repeated
ignition fails, shutdown power to the unit and contact a
service person.
4. For models with control valve knobs, each burner is
controlled by individual Hi-Lo control valves which have a
high flame setting and low flame setting.
5. Models supplied with an optional no access control
panel cover are designed for store locations to pre-set
the controls in one position for the same consistent
temperature setting. Once the valves are position in the
desired position the cover is placed over the controls to
prevent anyone from adjusting them.
Shut Down
1. For shutting down overnight, on all models turn the
power switch(es) to the "OFF" position.
2. When shutting down for longer periods, turn the power
switch(es) to the "OFF" position and turn the manual
supply shut off valve to the "OFF" position.
Final Preparation
New units are wiped clean with solvent at the factory to
remove any visible signs of dirt, oil, grease, etc., remaining
from the manufacturing process. They should be washed
with hot, soapy water to remove any solvent or oil residue or
installation dust or debris before using for food preparation.
Part # 4526671 (05/06/11)