Clearance Requirements – ProPress XL-C Press
Rings
B
B
A
A (min.)
Tube Dia.
Inches
2
1
/
"
4
1
/
"
2
8
3"
4
3
/
"
8
4"
5"
B
C
A
A (min.)
Tube Dia.
Inches
mm
2
1
/
"
4
1
/
"
105
2
8
3"
4
5
/
"
111
8
4"
5"
127
B (min.)
mm
Inches
mm
105
6"
152
111
7"
178
127
8"
203
B (min.)
C (min.)
Inches
mm
Inches
mm
6"
152
4
1
/
"
114
2
7"
178
4
7
/
"
124
8
8"
203
5
3
/
"
146
4
ProPress
®
Fitting System
A
C
A (min.)
Tube Dia.
Inches
mm
2
1
/
"
6
3
/
"
157
2
16
3"
7
7
/
"
189
16
4"
8
1
/
"
205
16
Tight Quarter Pressing Procedure – Pressing Rings
1. Place the press ring
around the fitting from
the front...
3. Keep the press ring
closed and rotate about
the fitting until the open-
ing is toward the front.
B
B (min.)
C (min.)
Inches
mm
Inches
mm
6
15
/
"
176
7
7
/
"
62
16
16
8
13
/
"
224
2
7
/
"
62
16
16
10
7
/
"
265
2
7
/
"
62
16
16
2. ...until the press ring is
resting in the groove
of the fitting.
4. Insert the press ring
actuator and start the
press cycle.
13