Electric Shock; Safety Instructions - Lowara BG Instructions Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Meaning of the symbols used in this manual
ATTENTION
1
Uses
BG, CEA, CA, HM: electric pumps for handling clean non-aggressive water free from dissolved gases, in civil and
industrial water distribution systems, irrigation. Only the self-priming models BG and BGM GARDEN can be used in
water with a with moderate gas (air) content.
CEA..V, CEA..N, CA..V, CA..N, CO, CO..K, HMS: special versions for handling moderately chemically aggressive
liquids or particular mixtures. Only model CO can be used with a moderate presence of solid bodies in the liquid *.
2
Working limits
• Max. operating pressure 800 kPa (8 bar)
• Liquid temperature: see table 1.
• Max. ambient temperature: 40°C
• Max. number of starts per hour: 40
• Max. free passage for suspended solids: 11 mm (CO 350...), 20 mm (CO 500...) *
Please contact our Sales and Service Department if:
- you must pump liquids with a density and/or viscosity value exceeding that of water (such as water and glycol
mixture) as it may be necessary to install a more powerful motor
- you must pump chemically treated water (softened, deionized, demineralized, ...)
and for any situation other than the ones described, related to the nature of the liquid and/or the installation.
Unless otherwise specified, for products with a mark of approval, the approval refers exclusively to the electric pump.
3

Safety instructions

ATTENTION
DANGER
Failure to observe this warning may cause personal injury

ELECTRIC SHOCK

Failure to observe this warning may result in electric shock
ATTENTION
Failure to observe this warning may cause damage to property (pump, system, panel,....)
or to the environment
Read the manual carefully before proceeding
Specific information for personnel in charge of installing the product in the system
(plumbing and/or electrical aspects) or in charge of maintenance
Specific information for users of the product
Pay attention to the working limits. Improper use may damage the pump and other
property, and injure people.
The product must be lifted and handled with care.
Do not use this electric pump to handle flammable and/or explosive liquids, or liquids
containing abrasive, solid or fibrous substances.
Pay attention to the risks deriving from accidental leaks of fluid.
The appliance is not intended to be used by persons (including children) with reduced
physical, sensory or mental capacities, or who lack experience or knowledge, unless,
through the mediation of a person responsible for their safety, they have had the benefit of
supervision or of instructions on the use of the appliance. Children must be supervised to
ensure that they do not play with the appliance.
The water and electrical connections must be made by qualified technicians (authorised
plumber/electrician) in compliance with the installation regulations in force.
The BGM..GARDEN version is not a portable appliance. Do not hold the pump by its
handle during operation.
Use the pump only within the limits specified on the rating plate (fig. 13 ref. A)
Do not run the pump with the flow port closed or dry.
Provide adequate ventilation for motor cooling purposes.
Protect the pump from the weather, avoiding ice formation.
Make sure that the rated voltage and the mains voltage are compatible (fig. 13 ref. B).
As additional protection from lethal electrical shock, install a high-sensitivity differential