This mode permits the automatic operation through a programming
unit.
To do this: Press the MODE button until the LED function light
« PROG » is on.
Signals through the
programmer
STOP
ECONOMY (Set back)
ANTI-FROST
Please note that when ECONOMY, COMFORT or ANTI-FROST MODE is chosen by the user, priority
is given to the ANTI-FROST and STOP orders sent by a programming unit. The function light "PROG"
flashes when orders are received by the appliance.
MODE chosen
by user
DISPLAY SETTINGS (THERMOSTAT / THERMOMETER):
Exceptionally, it may occur that there is a gap between the displayed temperature and your
thermometer. In this case, it is possible to harmonize the two settings.
This setting can be achieved only if your appliance is set between 17 and 23° C.
All doors and windows must be closed.
Wait for the stabilization of the temperature in the room (at least 6 hours) and avoid
as much as possible whereabouts in the room.
The temperature control should be placed in the middle of the room at 1.20 m from the
floor. Do not place it on any furniture.
Set the comfort temperature with the MODE button, e.g. 19.
Push for 6 seconds on MODE, this will offer two possibilities:
1. Display is flashing 19, a modification is possible:
•
•
« PROG » MODE:
Displayed symbols
PARTICULARITIES:
Anti-Frost signal
19
EC
HG
Correct with the + and - buttons
Confirm with MODE
Heating stops instantly
Set back of 3.5° C below
the comfort temperature
Holds temperature at
~7°C to avoid frost
MODE by programmer
Stop signal
=English Version=
Operation
damage
15