10.3
FLAME CHARACTERISTICS
It's important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ame
appears abnormal call a service person.
B36
10.4
OPTIONAL ANTI CONDENSATION SWITCH
(MODELS B36NTRE/B36PTRE/GX36NTRE-1 & GX36PTRE-1 ONLY)
This appliance has the option to change from an electronic intermittent pilot ignition (IPI) to a standing pilot for
cold climates. The anti condensation control (standing pilot) is located in the center of the control panel. Using
your finger, flip the switch up for standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot fl ame burning to burn continuously. This mode will minimize the
condensation which forms on the inside of the glass when the main burner is first turned on. It will also help
the fireplace and vent system stabilize more quickly during the colder winter months.
During the warmer winter and summer months, the ACS switch can be turned off to minimize fuel
consumption.
GX36-1
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
THERMOCOUPLE &
THERMOPILE
54.2A
MILLIVOLT
ILLUSTRATED
W415-1678 / B / 03.27.17
63