Warning
• This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial
or industrial settings and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful
observation of the indications provided in the manuals / instruction sheets supplied with those products.
• Cut off the power supply before carrying out any maintenance procedures.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and
make sure the system created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the
indications provided in the manuals / instruction sheets. Any repair work must be carried out: for the products themselves,
exclusively by Comelit Group S.p.A., for systems, by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the
indications and warnings contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to
change the information provided in this manual / instruction sheet at any time and without prior notice.
Art. 1468 is a network interface which allows the
installation of ViP devices in various LANs. An art. 1468
must be installed in each VLAN to route ViP system
communications over other VLANs. The IP addresses
of the other art. 1468 installed in the VLANs must be
programmed in every art. 1468 for the information to
be routed properly. A third-party VPN connection is
required for installation in remote networks. Art. 1468 is
configured with a static IP address.
DESCRIPTION Fig. 1 (page 2)
1. Ethernet
port
(default:
192.168.1.100, netmask 255.255.255.0)
2. Dip-switch
to
perform
predetermined network settings" and "Restore
factory settings" procedure.
3. Power supply input via 1441, 1441B .
4. CV1 and CV2 for setting port A2
5. CV3 and CV4 for setting port A3
6. A4 NO-POE Ethernet port for PC or router
connection
(default:
192.168.1.100, netmask 255.255.255.0).
7. A3 "POE" Ethernet port, can be set as NO POE
(default:
"Static
IP
netmask 255.255.255.0).
8. A2 "POE" Ethernet port, can be set as NO POE
(default:
"Static
IP
netmask 255.255.255.0).
9. A1 "POE" Ethernet port (default: "Static IP
address" 192.168.1.100, netmask 255.255.255.0).

MAIN FEATURES

Compatible system
DIN rail mounting
DIN modules (no.)
Power supply voltage
Min/max power consumption
Operating temperature
Operating relative humidity
IP protection rating

CONFIGURATION

This operation requires a PC loaded with the software
ViP Manager version 2.8.1 or later.
"Static
IP
address"
the
"Reboot
with
(Fig. 2)
(Fig. 2)
"Static
IP
address"
address"
192.168.1.100,
address"
192.168.1.100,
ViP
Yes
4
48 ÷ 56 Vdc
50 mA
+5 to +40 °C
25 to 75%
IP30
The ViP Manager software is available to download free
of charge from the website pro.comelitgroup.com
RESTORE PREDETERMINED NETWORK SETTINGS
This procedure is used to restart the product with
the default network parameters (192.168.1.100) while
keeping the remaining settings unaltered.
√ DIP in default position (OFF)
1. Cut off the device power supply
2. Set DIP1 to ON
3. Restore the device power supply
4. Wait for approximately 20-40 sec., until the
LEDs flash slowly and alternately (1 sec.
red / 1 sec. green)
5. Reset all the DIP-switches to OFF
» The green LED will flash for 5 seconds
» The device will start up with the default
network settings applied
6. The next time the device is restarted, the saved
parameters will be restored

RESTORE FACTORY SETTINGS

This procedure is used to restore the factory settings
for all parameters.
√ DIP in default position (OFF)
1. Cut off the device power supply
2. Set all the DIP-switches to ON
3. Restore the device power supply
4. Wait for approximately 20-40 sec., until the
LEDs flash rapidly and alternately (0.1 sec.
red / 0.1 sec. green)
5. Reset all the DIP-switches to OFF
» The red LED will flash for 5 seconds
» The device will restore all parameters
to the factory settings and restart in the
normal way
OFF
1
2
OFF
1
2
OFF
1
2
OFF
1
2
1 2
OFF
1
2
7