Pull the ventilating hose (Fig. 26, 1) at the
top from the gun body. Screw off the valve
cover (2). Remove the diaphragm (3). Clean
all the parts carefully.
Unscrew the union nut (Fig. 27, 1) and
remove the air cap (2) and nozzle (3). Clean
the air cap, nozzle seal (4) and nozzle with a
brush and solvent or water.
Clean the spray attachment and the
exterior of the container with a cloth that
has been soaked in water or a solvent.
Assemble the parts again (see "Assembly").
Assembly
The unit may only be operated with an integer
diaphragm (Fig. 26, 3).
Place the diaphragm (Fig. 26 ,3) with the
pin facing upwards on the bottom section
of the valve. Also see the marking on the
gun body.
Place on the valve cover (Fig. 26 ,2) and
screw it closed.
Place the ventilating hose (Fig. 26, 1) on the
valve cover and on the nipple at the gun
body.
Push the nozzle seal (fig. 28, 4) over the
needle (5); the groove (slot) should point
towards you.
Put the nozzle (Fig. 28 ,3) onto the gun
body and find the correct position by
turning it.
Put the air cap (Fig. 27, 2) onto the nozzle
and tighten it using the union nut (1).