WallPerfect Flexio 995
WallPerfect Flexio 995
24.
Interruption of Work
•
Turn the machine off. (Set the multifunction switch to "OFF")
•
Put the spray attachment on the floor.
•
When processing 2-component varnishes, clean the device immediately.
•
Clean nozzle openings after an interruption in operation.
25. Switching off and cleaning the spray attachment
Proper cleaning is the prerequisite for problem-free operation of the paint application
device. No warranty claims are accepted in case of improper or no cleaning.
The Clean function on the multifunction
i
switch may not be used when cleaning the
spray attachment.
•
Turn the machine off. (Set the multifunction switch
to "OFF")
•
Press the hook (Fig. 24 "click") slightly downwards.
Turn the spray attachment and grab handle
towards each other and detach.
•
Unscrew the container. Empty any remaining
coating material back into the material tin.
•
Preclean the container and feed tube with a brush.
Clean the ventilating bore (Fig. 25, 1)
•
Pour water or solvent into the container. Screw the
container back on.
Do not use flammable materials for cleaning
purposes.
•
Re-connect the spray attachment and the grab
handle.
•
Turn on the machine and spray the water or
solvent into a container or a cloth.
•
Repeat the above procedure until the water or
solvent emerging from the nozzle is clear.
•
Turn off the machine and remove the plug.
•
Press the hook (Fig. 24 "click") slightly downwards.
Turn the spray attachment and grab handle
towards each other and detach.
•
Screw of the container and empty it. Pull out the
suction tub with container seal.
CAUTION! Never clean seals, diaphragm and nozzle
or air holes of the spray gun with metal objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited extent. Do
not immerse in solvent, only wipe.
click
1
GB
D
53
53