english
GB
cleaning/maintenance
N.B. Before internal cleaning, switch off unit.
Cleaning Instructions
Important Cleaning Instructions
13
Cared for correctly, stainless steel has the ability to resist corrosion and pitting for many years.
The following weekly cleaning regime is recommended:
a. Exterior: Use a proprietary stainless steel cleaner following the manufacturers instructions.
b. Interior: Wash with soapy water, rinse and dry thoroughly.
WARNING:
High alkaline cleaning agent or those containing bleaches, acids and chlorines are very harmful to
stainless steel. Corrosion and pitting may result from their accidental or deliberate application.
If any of these liquids should come into contact with the unit during general kitchen cleaning,
wipe down the affected area immediately with clean water and rub dry.
Never use wire wool or scouring powders on stainless steel or aluminium surfaces.
After cleaning allow the unit to reach its normal operating temperature before reloading with
product. During usage all spills should be wiped clean immediately but care should be taken not
to touch the interior of freezer units (warm skin can 'freeze' to metal) or heated cabinets.
Condenser/
Clean the condenser filter, located in the unit compartment, when it becomes dirty (see Alarms and
14
Condenser Filter
Warnings in the User Operation Guidelines). Switch off the unit. Remove the condenser filter as shown.
Remove the unit cover on bottom mounts. On counter units, remove the two screws located at the base of
the condenser compartment unit cover (a) and remove condenser filter as shown below in fig (b) & (c). Wash
in warm soapy water, rinse and thoroughly dry before replacing. Also clean the condenser using a soft brush
or vacuum cleaner. NOTE: if there are any stubborn grease deposits etc left on or through the condenser call
CLEAN FILTER
your local service company to carry out a full service. Once the condenser/ condenser filter has been cleaned,
<<
Clear
switch on the unit. From the 'Supervisor Menu' (Supervisor Instructions) press button 2 (Alarms). The display
will show the 'Alarm' menu. Press button (Clear), followed by button 4 (<<). This will clear the Clean Filter
warning message, and the display will return to 'User Main Menu' for 1 minute before returning to the
'Normal Operating Display'.
Failure to carry out this action may invalidate the warranty of the condensing unit.
Cabinets
1
Top Mount
3
Counters
a
These should be inspected on a regular basis and replaced if damaged. To clean, wipe with a warm damp
15
Door Gaskets
soapy cloth followed by a clean damp cloth and finally thoroughly dry before closing the door.
Remove the shelves and trayslides (see Installation Instructions). To remove the support uprights lift vertically
Shelf Supports,
16
and pull away. The retaining studs remain attached to the internal wall. To replace, ensure the "keyhole"
Trayslides & Shelves
slots in the rear of the plastic moulding engages the retaining stud. The shelves and trayslides are dishwasher
safe. Wash the vertical supports with warm soapy water, rinse and thoroughly dry before replacing.
Shelf Supports (Fish and Heated cabinets)
To remove, loosen the locating screw and lift from the 'keyhole' fixing.
Wine Racks (Wine option - cabinets)
To remove, unscrew the thumb screw holding the rack to the rear of the cabinet and carefully lift out.
6
2
Bottom Mount
c
b
Bedienung der Steuerung
Foster Premier Controller (FPC)
Taste 1
Taste 4
Betrieb
Das Gerät ist betriebsfertig. Funktionsbeschreibung der Steuerung wie folgt.
7
Start und Selbstprüfung.
Erlischt nach ca. 3 Sekunden, wenn die
Selbstprüfung zu Ende ist.
Dann entweder
„Normalbetrieb" - Info-Display ohne Anzeige,
Temperatur-Display zeigt die Innentemperatur an
oder
„Bereitschaft". Das Gerät wird durch Drücken der
Taste 4 (On) eingeschaltet.
Im Info-Display erscheint das „Hauptmenü". Nach 1
Minute Übergang zum „Normalbetrieb".
*Sie können die Sprache bestimmen, in der die
Meldungen im Info-Display erscheinen - s. 9
„Einstellmenü".
Bedienung
8
Übergang in „Bereitschaft": Taste 1, 2, 3 oder 4
drücken. Im Info-Display erscheint:
Taste 1 (Off) drücken.
Zum Einschalten Taste 4 (On) drücken.
deutsch
D
Taste 2
Taste 3
FOSTER Ltd. 1A
TK-Heissg
- 2 0
Strom aus
On
- 2 0
Off
Abtauung
Service
Soll
- 2 0
Off
Abtauung
Service
Soll
15