14. Technische gegevens
Multimeter VC281:
Aanduiding ........................................................6000 counts (cijfers)
Meetsnelheid ....................................................ca. 2-3 metingen/seconde
Meetprocedure AC ............................................True RMS, AC-gekoppeld
Lengte meetkabels ...........................................elk ca. 90 cm
Meetimpedantie ................................................≥10 MΩ/10 pF (V-bereik)
Afstand meetbussen .........................................19 mm (COM-V)
Aanduiding vervanging batterij .........................≤6 V spanning
Aanduiding "gevaarlijke spanning" ...................≥30 V/AC-DC
Waarschuwing "overschrijding meetbereik" ......≥600 V/AC-DC, >60 A/AC-DC
Waarschuwing "OL"(overload) ..........................≥610 V/AC-DC, ≥60 A/AC-DC of meetweergave >6600 counts
Automatische uitschakeling ..............................ca. 15 minuten, handmatig te deactiveren
Stroomverbruik (Auto-Off) ................................<30 µA
Bedrijfsspanning ...............................................9 V-blokbatterij
Gebruikscondities .............................................0 tot +40 °C (<75 % rel. vochtigheid)
Gebruikshoogte ................................................max. 2000 m boven NAP
Opslagtemperatuur ...........................................-10 °C tot +50 °C
Gewicht .............................................................ca. 375 g
Afmetingen (l x b x h) ........................................178 x 85 x 40 mm
Meetcategorie ...................................................CAT III 600 V
Verontreinigingsgraad .......................................2
Veiligheid volgens .............................................EN61010-1
Stroomtang CLA60:
Tangopening .....................................................25 mm
Max. kabeldiameter ..........................................20 mm
Meetfunctie .......................................................DC, AC True RMS
Uitgang .............................................................10 mV/A
Lengte meetkabels ...........................................ca. 120 cm
Voeding.............................................................2x micro-batterij (AAA)
Gebruikscondities .............................................0 tot +40 °C (<75 % rel. vochtigheid)
Gebruikshoogte ................................................max. 2000 m boven NAP
Opslagtemperatuur ...........................................-10 °C tot +50 °C
Gewicht .............................................................ca. 184 g
Afmetingen (l x b x h) ........................................195 x 50 x 29 (mm)
Meetcategorie ...................................................CAT III 600 V
Verontreinigingsgraad .......................................2
Veiligheid volgens .............................................EN61010-1
140