PD 30 Y PD 40 Y PD 70 Y PD 7.4 Y
The engine functions properly if it does not exceed a maximum inclination of 20 °, both on the longitudinal and the
transversal axis. Should the engine be operated in conditions at a greater inclination, there is a risk of insufficient
lubrication or suction of engine oil from the air filter.
Before proceeding with charging the battery remove the cover from each cell.
Recharge the battery in a well ventilated place.
Interrupt charging if the electrolyte temperature exceeds 45 °C, (130 °F).
Do not disconnect the battery when the generator is running; the battery charger alternator and the electronic equipment
may irreparably be damaged.
Respect +/- polarity when connecting; failing this will cause a short-circuit when starting, which will irremediably
damage the electronic equipment.
Dispose of the acid can in an appropriate manner.
Battery fluid is a corrosive acid, extremely harmful to the skin. Always wear protective gloves and be extremely
careful to avoid spillage when pouring the acid.
In the event of contact, wash the affected part thoroughly with running water and consult a physician, in particular
when the eyes are involved.
The batteries develop hydrogen, a highly explosive gas. It is recommended not to smoke nor cause sparks in the
vicinity, in particular during charging.
Do not cause short-circuits by placing keys or tools on the batteries or on the cable fittings.