Troubleshooting

Fault
The cooling device
does not work. The fan
impeller does not
rotate.
The cooling device
does not work. The
ignition is switched on.
The cooling device
does not cool satisfac-
torily. The fan impeller
at the outside does not
rotate.
The cooling device
does not cool
satisfactorily. The fan
impeller at the outside
rotates.
8

Warranty

The statutory warranty period applies. If the product is defective, please contact your
retailer or the manufacturer's branch in your country (see dometic.com/dealer).
EN
Possible cause
There is no voltage
present in the DC
power socket in your
vehicle.
The DC power socket
is dirty. This results in a
poor electrical
contact.
The fuse of the
connecting cable is
burnt through.
The vehicle fuse is
burnt through.
The fan motor is
defective.
The fan motor for the
interior fan is defec-
tive.
The thermoelectric
element is defective.
The integrated power
unit is defective.
Suggestion
Switch on the ignition of your vehicle to
apply current to the DC power socket.
Clean the socket of the DC power socket
with a non-metallic brush and a solvent,
so that the middle contact pin is clean.
If the plug of your cooling device
becomes very warm in the DC power
socket, either the DC power socket must
be cleaned or the plug has not been
assembled correctly.
Replace the fuse (fig. 7 1, page 5) of the
DC plug with one of the same rating.
Replace the vehicle fuse of the DC power
socket (usually 15 A). (Observe the
operating instructions in your vehicle for
this).
Contact authorized service agent for
repair.