Technical Data; Identification Plate - DURAVIT Combi-System L Notice D'utilisation

Masquer les pouces Voir aussi pour Combi-System L:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
Problem
There are constant short
signal tones when activating
the water massage.
"Side jet" button flashes:
1x
2 - 4x and vibrates
5x and vibrates
! Do you want to acknowledge the error message?
> Press the corresponding button for 2 sec.
The button stops blinking. The whirltub is restarted but the error message appears
again.

10. Technical data

10.1 Identification plate

The identification plate is on the back page of the operating instructions or in the tech-
nical area of the whirltub.
This product conforms to all the appropriate EU guidelines.
DIN EN 12764, DIN EN 60335-2-60, IEC 60335-2-60
Potential cause
UV hygiene management is
defective.
Water level too low
Whirl system defective.
Water too warm (> 42 °C),
whirl system blocked.
Temperature sensor defective.
Solution
>
Disconnect the tub from the
mains.
>
Call customer service.
>
Report the number of signal
tones.
>
Add water until the water
level is about 5 cm above the
uppermost jet.
>
Call customer service.
>
Report the number of flash-
ing signals.
>
Add cold water.
>
Call customer service.
>
Report the number of flash-
ing signals.
37

Publicité

Table des Matières
loading

Table des Matières