Technical data

General data

Area
Order designation
PUO ID number
Communication profile
(DIN 19245 Part 1 and Part 3)
Communication medium
Drive profile
Network topology
PROFIBUS bus device
Baud rate [kbps]
Process data words
DP user data length
Max. number of bus devices
Max. cable length per bus
segment
External DC voltage supply

Operating conditions

Ambient conditions
Climate
Storage
Transport
Operation
Pollution
Degree of protection
EDK82ZAFPC−201 DE/EN/FR 7.0
Values
E82ZAFPC201
0x081B
hex
l
PROFIBUS−DP−V0
l
PROFIBUS−DP−V1
RS485
l
DRIVECOM profile "Drive technology 20" (can be switched off)
l
PROFIdrive (can be switched off, state machine and PROFIdrive
parameter data channel)
l
Without repeaters: line
l
With repeaters: line or tree
Slave
9.6 ... 12000 (automatic detection)
1 ... 10 words
(16 bits/word)
1 ... 10 process data words +
4 parameter data words
l
Standard: 32 (= 1 bus segment)
l
With repeaters: 125
1200 m (depending on the baud rate and cable type used)
+24 V DC ±10 %, max. 100 mA
IEC/EN 60721−3−1
IEC/EN 60721−3−2
Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
EN 61800−5−1
IP20 (protection against accidental contact according to NEMA 250 type 1)
l
1K3 (−25 to +60 °C)
2K3 (−25 to +70 °C)
Degree of pollution 2