7. LOGIC ADJUSTMENTS
TRIMMER
Trimmer for adjusting the pause (5-120 sec), or the time the door remains open with the TCA
is enable. The count begins at the end of the operating time for the opening phase or when
TCA
reaching the opening limit switch. It stops when a manual closing command is given and is
temporarily disabled when a stop command is given.
Trimmer for adjusting operating time (5-120 sec), or the time the overhead door takes to complete a ma-
neuver. The count begins each time a command is given. It is advisable to adjust the time to a few seconds
longer than is really necessary.
Note: the deceleration time can be fixed (1/3 or the work time) or adjustable:
With software version up to 3.00:
-
with fixed deceleration enabled (DIP 4 set to ON - DIP 8 set to OFF), set the TL to activate complete
closure. If deceleration is disabled (DIP 4 set to OFF - DIP 8 set to OFF), reduce the TL accordingly, to
compensate for the increased speed on closure.
-
with adjustable deceleration enabled (DIP 4 set to ON - DIP 8 set to ON), with work time (TL) remains
set at 48 sec. Adjust the trimmer TL to set the deceleration time as required (0-48 sec).
With software version up to 3.10:
-
with DIP4 set to OFF (no deceleration applied): the work time can be set from 4 to 48 sec.
-
with DIP4 set to ON (settable deceleration applied): the work time is established by the SETUP proce-
dure.
WORK TIME AND DECELERATION SETUP PROCEDURE
TL
By moving DIP4 from OFF to ON, or on power-up with DIP4 set to ON and the work time not memorised,
the stroke setup procedure is activated. Led DL7 flashes quickly.
PROCEDURE WITHOUT LIMIT SWITCHES INSTALLED:
1
Press the key AP/CH to start closure of the automation leaf.
2
When the leaf is closed, press the key AP/CH. The automation inverts movement and starts opening.
3
Press AP/CH when deceleration is required
4
Press AP/CH when the leaf reaches the completely open position.
5
LED DL7 lights up permanently (procedure completed and parameters memorised).
Note: if the limit switches are not installed, "generous" time settings are recommended.
PROCEDURE WITH LIMIT SWITCHES INSTALLED:
1
Press the key AP/CH to start closure of the automation leaf.
2
When the leaf reaches the closing limit switch, it must invert movement.
3
Press AP/CH when deceleration is required.
4
When the leaf reaches the opening limit switch, it must stop.
Note: STOP can be pressed at any time to repeat the procedure, starting from point 1.
obstacle detection sensitivity adjustment.
NOTE:
by rotating the TRIMMER FR clockwise the sensitivity of the gearmotor to obstacles
FR
diminishes and therefore the thrust force increases; vice-versa, by rotating it counter-clockwise,
the sensitivity of the gearmotor to obstacles increases and therefore the thrust force diminishes.
Selector for motor clutch adjustment, it has four positions for adjusting the motor torque to four
different levels. It is advisable to adjust this starting from a minimum value and increasing said value
RCM
if it is not sufficient to open the door, thus exerting the minimum torque needed to move the door
so that any accidental bumping against persons or property will cause the least possible damage.

DIP-SWITCHES

AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
3
NO REVERSE
after opening, the gate automatically closes when the delay set on the
On
T.C.A. trimmer expires.
Off
automatic closing disabled.
with automatic closing enabled, a sequence of open/close commands
On
causes the gate to OPENCLOSE-OPEN-CLOSE etc.
in the same conditions, the same command sequence causes the gate to
Off
OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
On
during opening the gate ignores any closing commands.
Off
the gate's behavior depends on the position of dip switch No.2.