It is strictly forbidden to check tightness by open
flame!
The cylinder must be placed in such a position so that
it is not in contact with the sheet metal of the burner
and the gas supply attached to it. The hose must not
touch (be in contact with) the hot back side of the
burner.
The device is supplied with a 40 cm long hose. The
hose must not be shortened or exchanged for a
longer one.
Inspect the condition of the hose regularly, at least
during each change of the cylinder.
In case of damage to the hose, it must be replaced
with a hose of the same construction, tested
according to DIN DVGVV.
Connection of the hose to the regulator must be done
with minimum of V4" left thread. The screw spanner
SW 17 is required for installation.
Twisting or distortion of the gas hose during the
installation of the hose and pressure regulator to the
liquid gas cylinder is not permissible.
Warning! The hose must not touch (be in contact
with) the hot back side of the burner!
Operation with pressure regulators other than those
prescribed above is prohibited.
Make sure the hose and regulator are changed after
5 years at the latest.
Connection of the liquid gas cylinder:
Take the protective cover of the valve off.
Take the covering nut from the attachment socket off
by turning (right).
Check the rubber seal in the cylinder valve (regulator
connection).
The regulator and the hose must be screwed on
tightly (left thread). No not use any tool or instrument.
Do not turn the regulator but the sleeve nut.
Check the tightness of the connection.
Change of the liquid gas cylinder:
Close the cylinder valve
Unscrew the regulator.
Screw the closing nut on the connecting tread (left
thread) – put the protective cover on.
Connect the new cylinder and check tightness.
Start up procedure / discontinuation or stopping procedure of
the catalytic stove:
Before operation, let the cylinder stand in a vertical
position for 1 hour if transported so the elements
more burdening to the environment may settle down
to the bottom of the cylinder.
Place the gas cylinder to the inner space of the
device (back side). Connect the gas cylinder as
described above.
Open the cylinder valve on the propane cylinder by
turning to the left.
1.) Turn the control knob to position 1/. Ignition; Pic. (3-C)
2.) Press and hold the START button; Pic. (3-B)
3.) Press the piezoelectric ignition button several times until
eternal flame is produced. Pic. (3-A)
4.) Hold the Start button pressed for about 20 seconds until
the flame is stable.
5.) If external flame of the burner fails to be ignited at the
first attempt, wait for about 30 seconds and repeat steps 2-
4. Setting the thermostat; Pic. (3-D)
Set the thermostat to an average temperature for switch-
off.
Set the gas heater to a full heating output (level 5) and let it
heat until the thermostat switches off.
(the flame will automatically diminish). Measure the
temperature in the room.
When the temperature in the room is too low, turn the
thermostat regulator (pic. 3-D) slightly more to the left. (the
flame will automatically increase)
If the temperature in the room is too high, turn the
thermostat regulator (pic. (3-D) to the right and let the
room cool down. (the flame will automatically diminish).
Do these actions for as long until the required switch-off
temperature is reached.
Now the temperature in the room will automatically be
controlled by the thermostat, which will automatically
increase or diminish the flame.
CAREFUL! Do not move when hot (transport).
The gas cylinder must not be turned during the
operation or shut down of heating device. The highest
danger of accident!
Shutting off of the catalytic gas heating device:
CLOSE THE GAS VALVE ON THE CYLINDER.
Service
Any technical questions? Complaint? Do you need
spare parts or operation manual?
Go to our website www.guede.com and the section
Service will help you quickly and without bureaucracy.
Please, help us to help you. In order to identify your device
in case of complaint, please indicate serial number, order
number and year of manufacture. All information is
available on the product label. To have all information
always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com