17) MALFUNCTION. CAUSES and REMEDIES
17.1) The roll-up door does not open. The motor does not turn.
1) Check that the photocells are not dirty, engaged or misaligned.
Proceed as required. Check the safety edge.
2) If the motor is overheated, the thermal protection may be activated.
Wait for self-resetting to take place.
3) Check that the motor and the start capacitor are correctly connected.
4) Check that the electronic components are correctly supplied with power.
Check that the fuses are undamaged.
5) By means of the control panel diagnosis LEDs (see respective instructions),
check whether the functions are correct. If any fault is found, identify the
cause. If the LEDs show that a start command persists, check that there
are no radio transmitters, start buttons or other control devices which
keep the start contact activated (closed).
6) If the control panel does not work, it must be replaced.
17.2) The roll-up door does not open. The motor turns but there is no
movement.
1) In the EF models, check that the electric brake is adjusted as shown in
paragraph 10.
2) Check that the drive pulley and all the operator components are undam-
aged.
WARNINGS
Correct controller operation is only ensured when the data contained
in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the
installation standards and the instructions contained in the present
manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.