5
Changing the angle reference value
With button (2), it is possible to transfer angles elsewhere. To do so,
set the device to the desired slope and press button (2). The display
then changes to „0.0°", „REF" flashes on the display and the required
reference angle is set. The slope can now be transferred to other objects.
Press button (2) again to deactivate the angle reference.
!
The angle reference is not deactivated by switching off
the device.
6
°C / °F / measured value
The ambient temperature is shown in °C and °F by briefly pressing
the CAL button (3). Press again to switch back to the measured
value.
7
HOLD
Press the HOLD button (5) to hold the current measured value
on the display.
8
Acoustic signal
The acoustic signal can be switched on or off with button (6).
When the angle of slope stands at 0°, 45°, 90° or the most recently
stored value, this is indicated by an acoustic signal.
!
When working with a changed angle reference value, the
acoustic signal is activated on reaching the new reference
value (0°, 45°, 90° display).
9
Backlighting
The backlighting is switched ON/OFF by pressing and holding button (6).
Auto Off function
In order to preserve the batteries, the measuring device switches off
automatically if it is left idle for 3 minutes.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies) before
storing for longer periods. Store the device in a clean and dry place.
12
EN