3.9 Maintenance and troubleshooting
3.9.1 Troubleshooting plan
Problem
Aduro DraftOptimizer is not
running.
Aduro DraftOptimizer runs but
does not extract enough.
Aduro DraftOptimizer is defect
3.9.2 Maintenance
When used regularly, the Aduro DraftOptimizer needs maintenance corresponding to the periodical
chimney sweep visits. However, at least once a year the Aduro DraftOptimizer should be cleaned
thoroughly by an expert.
IMPORTANT! Disconnect the power from unit before you start cleaning.
When cleaning, the top ring should be dismounted and the Aduro DraftOptimizer cleaned thoroughly
on the inside. The axial wing should be carefully cleaned to remove soot or it can be replaced. The
safety net must be cleaned from soot and dirt.
Cause
It needs current
Something prevents it from
rotating
Don't know
The ventilation system is not
tight
Low pressure in the house
The fireplace is too big
Defect parts must be replaced
24
Check
Is the socket outlet switched on
and does it function?
Is the plug in the socket outlet?
Is there current to the power
supply?
Is the power supply intact (light
in the diode)?
Have all the cords been
mounted correctly?
Are the cables defective?
Is there a lot of soot in the unit?
Are there any foreign bodies
(birds, branches)?
Contact dealer
Are smoke pipes, connections,
chimney and cleaning hatches
tight?
Does the exhaustion in the
house work? (Cooker hood,
exhaustion from bathroom,
tvangsstyret luftskifte?)
Is the efficiency of the fireplace
more than 15 kW?
Is the fireplace an open
fireplace?
Parts that are easily replaced:
Cooling house with engine
Axial wing
Engine print
Control box print
Speed regulator
Propeller