F
AERASGARD
Schéma de raccordement
1 2 3 4
shield
shield
1 2 3 4
Sensor
Plug for
VOC
display
Sensor
CO
2
ON
DIP A
1 2 3 4 5 6 7 8
address
°C
r.H.
VOC
CO ² CO ²
VOC
offset
zero
AERASGARD
®
Rxx - Modbus
Type ⁄ WG02
RCO2 - Modbus
RCO2-Modbus
RCO2-Modbus LCD
RLQ - CO2 - Modbus
RLQ-CO2-Modbus
RLQ-CO2-Modbus LCD
RFTM - PS - Modbus
RFTM-PS-Modbus
RFTM-PS-Modbus LCD
RFTM - CO2 - Modbus
RFTM-CO2-Modbus
RFTM-CO2-Modbus LCD
RFTM - CO2 - Modbus - P
RFTM-CO2-Modbus-P
RFTM-CO2-Modbus-P LCD
RFTM - LQ - CO2 - Modbus
RFTM-LQ-CO2-Modbus
RFTM-LQ-CO2-Modbus LCD
RFTM - LQ - PS - CO2 - Modbus
RFTM-LQ-PS-CO2-Modbus
RFTM-LQ-PS-CO2-Modbus LCD
Remarque :
®
RFTM - LQ - PS - CO2 - Modbus
R xx - Modbus
Sensor
Plug for
display
Sensor
CO
2
ON
DIP B
ON
DIP A
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
VOC
°C
r.H.
CO ² CO ²
offset
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
1 2 3 4
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Button
1 2 3 4
Sonde d'ambiance, resp. convertisseur de mesure, pour l'humidité, la température,
la qualité de l'air (COV), les particules fines (PM) et la teneur en CO2, Deluxe
plage de mesure
humidité
température
–
–
–
–
–
–
–
–
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
0...100 % h.r.
0...+50 °C
Ces appareils ne doivent pas être utilisés comme un dispositif de sécurité !
Schéma de raccordement
DIP A: Bus address
VOC
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Button
VOC
zero
Plug for
display
Sensor
CO
shield
2
ON
DIP B
ON
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
shield
CO ²
zero
PM
CO2
–
5000 ppm
–
5000 ppm
–
5000 ppm
–
5000 ppm
0...1000 µg/m
3
0...1000 µg/m
3
–
5000 ppm
–
5000 ppm
–
5000 ppm
–
5000 ppm
–
5000 ppm
–
5000 ppm
0...1000 µg/m
3
5000 ppm
0...1000 µg/m
5000 ppm
3
26
Sensor
1 2 3 4
CO
shield
ON
DIP B
1 2 3 4 5 6
mode
shield
1 2 3 4
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
Reception (LED green)
Error (LED red)
Shielding
Button
DIP A
LED (internal status)
Potentio-
meter
écran
référence
☼
COV
=
P
–
1501-61B0-6001-200
–
■
1501-61B0-6021-200
0...100 %
1501-61B1-6001-500
0...100 %
■
1501-61B1-6021-500
–
–
1501- 2116-6001- 200
–
–
■
1501-2116 -6021- 200
–
1501-61B6-6001-200
–
■
1501-61B6-6021-200
☼
–
1501-61B6-6501-271
☼
–
■
1501-61B6-6521-271
0...100 %
1501-61B8-6001-500
0...100 %
■
1501-61B8-6021-500
0...100 %
1501- 2119-6001- 500
0...100 %
■
1501-2119 -6021- 500
Rev. 2021 - V30
RFTM - CO2 - Modbus - P
Plug for
display
2
ON
DIP A
1 2 3 4 5 6 7 8
address
Potentio-
meter
CO ²
zero
D
D
(B
T
R
E
S
B
L