The use of 869.700 - 870.000 MHz frequencies band has been harmo-
nised in Europe. The use of 433.050 - 434.790 MHz frequencies band
has not been harmonised in Europe yet: Check for possible limita-
tions in the country of use.
For example, some European countries only permit the use of this ra-
dio equipment in the 434.050 - 434.790 MHz frequency band.
Radio frequency transmission operates inside frequency bands permitted by
European regulations that are valid when the radio remote control is put on the
market.
Each radio remote control is programmed by the producer in the AUTOMATIC scan
mode (producer's standard programming) or MANUAL selection mode.
When operating in the MANUAL selection mode it is possible to operate at a specific
frequency that must be set manually by programming the dip switches in the radio
modules (see paragraph 8 "Programming").
To set or modify this operation mode contact personnel that have been author-
ised by Autec.
When operating in the AUTOMATIC scan mode it is possible to operate at a specific
frequency, which can be changed in case of interference or conflict with other radio
system using the "Changing the operating frequency" procedure.
This mode allows to change the operating frequency without internal interventions on
the transmitting unit or the receiving unit.
1 With the transmitting unit started (blinking green LED):
- press the START pushbutton (or use the selector switch)
and hold it down (a)
- press the STOP pushbutton (b)
- finally release the START pushbutton (or the selector
switch).
2 Unlock the STOP pushbutton by turning
it as shown in the photo and repeat the
starting procedure.
N.B.: During the work frequency changing process, the receiving unit loses radioelec-
tric connection with the transmitting unit.
After starting, some seconds may be necessary to reset connection, therefore keep
the START pushbutton pressed for about 8-10 seconds.
LIESNMU4

7 FREQUENCIES

MANUAL SELECTION MODE
AUTOMATIC SCAN MODE
Changing the operating frequency
7 - Frequencies
b
a
Page 29 of 80

Publicité

Table des Matières
loading