Use the extension if attached separately.
Compressed air connection:
Connect the maintenance unit with the filter pressure
control valve and the oil mist lubricator.
To ensure continuous and long-term operation, the
appliance must be constantly supplied with pneumatic
oil.
We recommend:
The Güde mini-lubricator can be received under Art.
No. 41086 and Güde pneumatic oil under Art. No.
40060
Release the lock if applicable.
Set the necessary pressure.
Apply the switch fuse or guide plate on the workpiece
while exerting strong pressure.
Connect the appliance
with the air intake hose.
Do not aim the appliance
at yourself or other
persons.
1
Press the clamping lever
and move the magazine
back to open.
2
Insert clamps/nails in the
magazine. The appliance
must not be filled if the
trigger is pressed.
3
Move the magazine back
to enable the clamping
lever to fit in.
4
As soon as you want to continue in your work, start
with step 3 of this chapter.
After finishing your work
Disconnect the quick-acting coupling from the
extension.
Empty the magazine.
Blow the appliance with compressed air.
Store the appliance safely.
Warranty
A warranty period of 12 months applies to commercial use
and 24 months apply to private use and commences on
the day of purchase of the device.
Warranty applies exclusively to failures due to defective
material or workmanship. An original sale slip with
indication of date of sale must be presented in case of
claiming for the warranty rights.
To fire a clamp/nail, pull
the trigger.
5
Remove the air inlet hose
if the cover is blocked or if
you want to finish your
work.
6
Press the clamping lever
and move the magazine
up to open.
7
Or remove the blocked
clamps or nails.
8

Publicité