2. TRANSPORT AND INSTALLATION.

2.1. TRANSPORT AND PACKAGING

Knocks a nd sudde n movements must be a voide d when tra nspo rting the equipment. In a ny ca se, the pa cka g ing
must be protected from wa ter.
HANDLE THE EQUIPMENT CAREFULLY, IT WILL LAST LONGER !

2.2. ELECTRICAL SUPPLY INSTALLATION.

The electrica l insta lla tion of the equipment ma king up the system must be ca rried out by spe cia lised pe rsonnel
a ccording to the a pplica ble sta nda rds.
The loca tion must fulfill the following conditions:
Pla ce: Dry a nd ventila ted. Fa r enoug h a wa y from the welding a rea in orde r to prevent the dust ca used by
-
the welding process from g etting into the equipment. Never work in the ra in.
The distribution pa nel where the ma chine ha s to be connected must ha ve the following elements, a t lea st:
-
CABLE PLUG
"SCHUKO "
2 P + T 1 6 A
CABLE PLUG
"CETAC"
2 P + T 3 2 A
The connection to the ma ins is ma de by the input hose. IMPO RTANT! Verify tha t the wire is connected to a plug
with a n efficient ea rth ta p.
If you ha ve spe cia l equipment, with po wer supply volta g e other tha n 2 3 0 V, you will find the da ta for de fining the
necessa ry electrica l insta lla tion on the equipment cha ra cteristics pla te.
Any supply volta g e tha t is outside the ra ted ma rg in g ives rise to the a ctiva tion of the protection system, preventing
the welding ope ra tion.
Leng th
5 m
Up to 1 5 0 m
> 1 5 m Up to 5 0 m
SMART 2 0 0 MP
SO CKET AND ELECTRICAL PRO TECTIO N DEVICES
SO CKET AND ELECTRICAL PRO TECTIO N DEVICES
SMART 2 0 0 MP
CRO SS-SECTIO N
4 mm
2
4 mm
2
6 mm
2
SO CKET
MAG NETO THERMAL
SWITCH
DIFFERENTIAL
CIRCUIT-BREAKER
SO CKET
MAG NETO THERMAL
SWITCH
DIFFERENTIAL
CIRCUIT-BREAKER
If it is necessa ry to use a long er power supply hose or a
connection to a n extension, keep in mind the va lues of this
ta ble. These va lues a re for reference a nd a re influenced by the
sta te of the conductors, connections a nd a mbient tempera ture.
1 6
2 P 1 6 A + TT
2 P 1 6 A-(2 3 0 V)
2 P 2 5 A / 3 0 0 mA
2 P 3 2 A + TT
2 P 2 5 A-(2 3 0 V)
2 P 2 5 A / 3 0 0 mA