Pentair ControlPro Garantie Et Guide D'installation page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
B7 Temperature sensor Inputs
The temperature sensor H-52-0272 supplied with the system need to be connected to the 'Pool' terminals.
The sensor measures the water temperature and uses this input to control filtration and heating. We recommend
fitting the sensor in the water circuit before the filtration pump.
Drill a 10 mm hole in the pipe.
Fit the sensor in the hole.
Use the hose clamp supplied with the system to fix the sensor.
When using ControlPro with solar panels a second optional sensor H-52-0272 is required. Fit it in a position near the
solar panels (see mounting example below)
Water temp sensor mounting
Be careful not to overtighten the hose clamp in order to avoid damage on the sensor.
CT1 and CT2 Control Unit connection
The Control unit comes fitted with a 4 m long cable that connects to the
'Controllers CT1 'terminals. Connect the colors as indicated below.
RED
+ terminal
BLACK
- terminal
GREEN
A terminal
BLUE
B terminal
If a longer cable is required (up to 50m is possible.) :
Access the Control unit by carefully unscrewing the 4 screws on the back
of the unit.
Unscrew the terminal and fit the new cable. The terminals inside on
Control unit and the Interface Module have to match.
As an option it is possible to fit a second Control Unit using the same method as
decribed above using the CT2 terminals.
The Controller is available as part number CPRO-2010.
12VDC Power for the Control Unit(s) is supplied by the Interface Module
You can now close the Din rail cabinet and power up the system for testing and configuration. The display should light
up and the ON/OFF LED on the interface module should be lit . This led will blink while starting up. If it keeps blinking,
please verify the connections and configuration.
Solar Panel sensor mounting
11

Publicité

Table des Matières
loading

Table des Matières