Basic Information (General); Proper Use; Improper Use; Warranty - KERN FCB Série Mode D'emploi

Masquer les pouces Voir aussi pour FCB Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3 Basic Information (General)

3.1 Proper use

The balance you purchased is intended to determine the weighing value of material
to be weighed. It is intended to be used as a "non-automatic" balance, i.e. the
material to be weighed is manually and carefully placed in the centre of the weighing
plate. As soon as a stable weighing value is reached the weighing value can be read.

3.2 Improper Use

Do not use balance for dynamic weighing. In the event that small quantities are
removed or added to the material to be weighed, incorrect weighing results can be
displayed due to the "stability compensation" in the balance. (Example: Slowly
draining fluids from a container on the balance). Do not leave permanent load on the
weighing plate. This may damage the measuring system. Impacts and overloading
exceeding the stated maximum load (max) of the balance, minus a possibly existing
tare load, must be strictly avoided. Balance may be damage by this.
Never operate balance in explosive environment. The serial version is not explosion
protected.
The structure of the balance may not be modified. This may lead to incorrect
weighing results, safety-related faults and destruction of the balance.
The balance may only be used according to the described conditions. Other areas of
use must be released by KERN in writing.

3.3 Warranty

Warranty claims shall be voided in case
• Our conditions in the operation manual are ignored
• The appliance is used outside the described uses
• The appliance is modified or opened
• Mechanical damage and damage caused by media, liquids
• Natural wear and tear
• The appliance is improperly set up or incorrectly electrically connected
• The measuring system is overloaded

3.4 Monitoring of Test Resources

In the framework of quality assurance the measuring-related properties of the
balance and, if applicable, the testing weight, must be checked regularly. The
responsible user must define a suitable interval as well as type and scope of this
test. Information is available on KERN's home page (www.kern-sohn.com) with
regard to the monitoring of balance test substances and the test weights required for
this. In KERN's accredited DKD calibration laboratory test weights and balances may
be calibrated (return to the national standard) fast and at moderate cost.
8
FCB-BA-e-1614

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fcb 3k0.1Fcb 6k0.5Fcb 8k0.1Fcb 12k1Fcb 24k2Fcb 30k1

Table des Matières