6.5. Alarm management

LOW FLOW
Whenever the installed sensor detects an insufficient water flow inside the UV reactor, the system
disconnects the UV lamp and the "Flow" indication of the screen will flash.
WARNING:
Once restored the water flow, the system automatically resets.
LOW RADIATION
Whenever the radiation sensor installed in the reactor detects too low values to ensure a minimum
2
dose of 60 mJ/cm
, even with the lamp running at 100% of its rated power, the "Radiation" indication
of the screen will flash.
HIGH WATER TEMPERATURE
Whenever the temperature sensor installed in the UV reactor detects a water temperature higher
o
o
than 113
F (45
C), the system disconnects the UV lamp and the indication of "Temperature" of the
screen will flash.
CONTROL PANEL OVERHEATING:
o
o
The control panel is designed to work always at internal temperatures below 113
F (45
C). If for any
reason (excessive external temperature, failure of internal cooling fan, etc.) the temperature reaches
higher values, the system will automatically disconnect the UV lamp power leaving the internal
cooling fan running until the inside temperature drops below this value .
Overheating indicator will flash on the top of the screen.
WARNING:
Temperature control is made by the thermostat [F0] inside the control panel, so that in no case its
o
o
factory setpoint temperature 113
F (45
C) must be modified.
Once solved the problem, it is necessary to restart again the system pressing the RUN key.
ACTIVE ALARM / ALARM LOG
Whenever the system detects that an alarm is active, disconnects the UV lamp.
The system will not allow its re-initialization until the alarm condition disappears and the user makes
an acknowledgement by clicking the icon.
Clicking this icon, a list of all the alarms currently active will be visible.
20