If the DMSD Lite process monitoring system is
active in addition to the job, a job error message is
also displayed at each DMSD Lite error message.
Depending on the settings made in the app, this
job error message will be displayed after acknowl-
edgement of the DMSD Lite error message.
Acknowledge the error message by pressing the
"OK key" (T).
The warning message "DMSD NOK" indicates the
type of error (force or stroke) that has occurred.
Acknowledge the error message by pressing the
"OK key" (T).
If a DMSD Lite password has been set in the app,
this password has to be entered before the riveter
is enabled.
The standard DMSD code is 1111. The DMSD
code can only be changed via the app.
The warning message "Mandrel Cup Missing" in-
dicates that the stud collector is missing or has not
been correctly or completely screwed on.
Screw on the stud collector again.
The riveter is then ready for operation. Acknowl-
edgement with the "OK key" (T) is not necessary in
this case.
40 | English