Restoring Factory Settings; Changing The Dome - Abus TVIP91 Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 112
6.11 Restoring factory settings (reset)
Resetting the password for "master" access
1. Turn off the camera.
2. Press and hold the "PW reset" button on the camera.
3. Now connect the power supply to the camera (using 2-pin power supply or Power over
Ethernet) and hold down the "PW reset" button for a further 60 seconds.
Reset all camera settings
1. Turn off the camera.
2. Press and hold the "Reset" button on the camera.
3. Now connect the power supply to the camera (using 2-pin power supply or Power over
Ethernet) and hold down the "Reset" button for a further 60 seconds.
Further use of the reset buttons
This function only applies for TVIP92100, TVIP92300, TVIP926X0 and TVIP92700.
If the camera has finished its start-up process (status LED inactive, LED for power supply active),
the two reset buttons preserve the function for zooming in and zooming out.

6.12 Changing the dome

TVIP91300/TVIP92300/TVIP91700/TVIP92700
If required, there is a tinted dome available for the IP dome cameras specified (ABUS item
number TVAC31065).
The dome is installed as follows:
1. Remove the dome from the camera by loosening the four fixing screws (dome with dome
ring).
2. Remove the remove fixing screws on the underside of the dome.
3. Remove the dome from the dome ring.
4. Insert the tinted dome into the dome ring.
5. Place the fixing ring on the underside of the dome ring and screw in the four fixing screws.
79

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tvip92 série

Table des Matières