ENGLISH
NOTE:
Perform the function tests, teach-in processes, program
changes and extensions while standing in the garage.
8.1
Instructing users
Instruct all persons using the door system on the proper
▶
and safe use of the garage door operator.
▶
Demonstrate and test the mechanical release as well as
the safety reversal.
8.2
Function tests
8.2.1
Cord knob mechanical release
WARNING
Danger of injury due to a fast-closing door
Pulling the cord knob when the door is open can result in
serious injury. The door can close quickly, e.g. due to weak,
broken, defect springs or faulty counterbalance.
Only pull the cord knob when the door is closed.
▶
▶
Pull the cord knob when the door is closed.
The door is unlocked. The door must be easy to open and
close by hand.
8.2.2
Mechanical release by emergency release lock:
Only for garages without a separate entrance
When the door is closed, actuate the emergency release
▶
lock.
The door is unlocked. The door must be easy to open and
close by hand.
8.2.3
Safety reversal
To check the safety reversal:
1.
2.
In the event of a failure of the safety reversal, a specialist
▶
must be commissioned immediately for the inspection
and repair work.
8.3
Normal operation
In normal operation, the garage door operator is governed
exclusively by impulse sequence control.
An external button, a hand transmitter button or the T button
in the operator cover can activate the impulse sequence control:
1st impulse:
The door runs towards
an end-of-travel position.
2nd impulse:
The door stops.
3rd impulse:
The door runs in the opposite direction.
4th impulse:
The door stops.
5th impulse:
The door runs in the direction of the end-of-
travel position selected in the 1st impulse.
etc.
80
Stop the door with both hands
while it is closing.
The door system must stop and
initiate the safety reversal.
Stop the door with both hands
while it is opening.
The door system must switch off.
The door stops.
The operator light will light up during a door run and go out
after approx. 2 minutes.
8.4
Behaviour during a power failure
To open or close the garage door by hand:
Operate the mechanical release (see section 8.2.1 or
▶
8.2.2).
This way, you pull out the coupling slider and decouple
the slide carriage from the carriage coupling.
8.5
Behaviour following a power failure
After the power returns, the slide carriage must be re-coupled
to the carriage coupling.
1.
Move the carriage coupling close to the slide carriage.
2.
Push up the green coupling slider.
3.
Move the door by hand until the slide carriage snaps into
the carriage coupling.
4.
Push the hand transmitter button or a button with
impulse command.
If the power failure occurred during door travel, the operator
carries out a reference run with the first impulse command.
5.
Check whether the door completely reaches its OPEN
and CLOSE end-of-travel positions by conducting
multiple uninterrupted door runs.
If the behaviour does not correspond to that described in step
5, even after multiple uninterrupted door runs, new learning
runs are necessary. Delete the previous door data
(see section 11.2 and 5.1).
9
Inspection and maintenance
The garage door operator is maintenance-free.
In the interest of your own safety, we recommend having the
door system inspected and maintained by a qualified person
in accordance with the manufacturer's specifications.
Danger of injury due to unexpected door travel
Unexpected door travel can result during inspection
and maintenance work if the door system is inadvertently
actuated by other persons.
Disconnect the mains plug whenever performing work
▶
on the door system.
Safeguard the door system against being switched
▶
on again without authorisation.
Only specialists may perform inspections or repairs. Contact
your supplier for this purpose.
▶
Check all safety equipment and protective
functions monthly.
You must eliminate any errors or defects immediately.
▶
The operator can perform a visual inspection.
WARNING
TR10K009 RE / 02.2016