INSTALLATION
All Remote Drop-In Hot/Cold Wells are shipped in a shipping
frame for protection and stability. Keep the unit in the shipping
frame until the unit and the installation site are completely
prepared for the unit to be installed.
1. Remove all external packaging from the unit.
2. Remove tape, protective packaging, and literature from all
surfaces of unit.
NOTE: To prevent delay in obtaining warranty coverage, complete
online warranty registration. See the IMPORTANT
OWNER INFORMATION section for details.
3. Cut the appropriate opening in the countertop for the unit
being installed. Refer to "Countertop Cutout Dimensions"
in this section.
4. If installing the control box remotely, cut and drill the
appropriate holes in the vertical surface where the control
box will be installed. Refer to the "Installing the Remote
Control Box" procedure for cutout dimensions.
• The cutout depth required for the control box is
8-1/2" (216 mm).
5. Make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents.
6. Make sure the following interior clearances are available:
• A minimum 2" (51 mm) clearance between the
condensing unit and any combustible surface.
• A minimum 3-1/2" (89 mm) clearance between the
bottom of the Hydro-Heater and any combustible
surface.
NOTE: The countertop must be level to ensure proper draining
of the hot/cold well.
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
7. Lift the unit out of the wooden shipping frame and carefully
lower it into the countertop cutout. This step requires two
or more people, depending on the unit.
8. Apply National Sanitation Foundation-approved (NSF-
approved) silicone sealant around the edge of the unit to
seal it to the countertop.
9. Install the control box in the desired location, if installing
remotely.
• The control box can be installed remotely within 72"
(1829 mm) of the Hydro-Heater. Refer to the "Installing
the Remote Control Box" procedure in this section.
Countertop
Coutout
Installing a HCWBIR-3 Model
BURN HAZARD: Drain water may reach temperatures
in excess of 200°F (93°C). Use appropriate plumbing
materials when installing drain.
NOTE: Consult a licensed plumber for proper drain and water
supply installation that conforms to local plumbing
codes.
10. Connect the onsite drain line to the 3/4" Garden Hose
Thread (GHT) drain fitting on the front of the Hydro-Heater.
NOTE: Approved air gap or other back-flow prevention device
must be installed by a licensed plumber, if required.
11. For HCWBIR Models, install the condensing unit in the
desired location. Refer to the SPECIFICATION section for
installation dimensions.
• Make sure the installation site offers continuous air flow
ventilation to the condensing unit.
• Make sure there is a minimum of 6" (152 mm) of space
between all sides of the condensing unit and any
combustible surface.
Auto-Fill units must be installed with adequate backflow
protection and must conform with all federal, state, and
local codes.
12. Have qualified installers perform the "Connecting the
Components" procedure in this section.
13. Connect the onsite water supply to the 3/4ʺ GHT inlet
fitting for the Auto-Fill system on the bottom right side of
the Hydro-Heater. Refer to "Water Supply Specifications"
in the SPECIFICATIONS section of this manual for water
supply requirements.
3/4" GHT
Drain Fitting
Connecting the Plumbing Fittings
10
English
Hot/Cold Well
Well
Hydro-Heater
CAUTION
NOTICE
Hydro-Heater
Electrical
connection
to control
enclosure.
3/4" GHT
Inlet Fitting
Form No. HCWBIRM-0121